• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: MALLINCKRODT MANUFACTURING LLC INOMAX DSIR PLUS (DELIVERY SYSTEM); NITRIC OXIDE ADMINISTRATION APPARATUS

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

MALLINCKRODT MANUFACTURING LLC INOMAX DSIR PLUS (DELIVERY SYSTEM); NITRIC OXIDE ADMINISTRATION APPARATUS Back to Search Results
Model Number 10007
Medical Device Problem Code Gas/Air Leak (2946)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 04/06/2026
Type of Reportable Event Malfunction
Event or Problem Description
A customer located in the united states contacted (b)(6) on (b)(6) 2026 to report they experienced a no / n2 system leak with their inomax dsir plus device while a patient was receiving inhaled nitric oxide (no) therapy.The customer immediately utilized the inomax dsir plus device's inoblender to manually ventilate the patient and then replaced the dsir plus with a backup unit.The customer reported the patient remained in stable condition at the time of the event.The complaint device was returned to (b)(6) for investigation.An internal employee performed a service order review for inomax dsir (b)(6).Review of the service order determined that the no / n2 system leak was caused by a shutoff valve failure.As a result, these service order findings meet the criteria of a reportable malfunction as it was located at a user's facility and set to administer a dose of inhaled nitric oxide (no) at the time of the incident.
 
Additional Manufacturer Narrative
Reportable malfunction with inomax dsir plus (b)(6) was documented and investigated under (b)(4).The device was returned to a regional service center (rsc) for evaluation.The rsc also experienced the reported complaint of a no / n2 system leak during testing.Further investigation of the device found the leak was due to a shutoff valve failure.As a result, the shutoff valve was replaced, and the device passed all subsequent leak testing.The root cause for the no / n2 system leak was most likely due to a shutoff valve failure.Trends were reviewed for this reportable condition and determined to be within the established control limits.No further action is required at this time.A full functional test was performed and the device operated according to specifications.As a result, the device was placed back into circulation for customer use.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
INOMAX DSIR PLUS (DELIVERY SYSTEM)
Common Device Name
NITRIC OXIDE ADMINISTRATION APPARATUS
Manufacturer (Section D)
MALLINCKRODT MANUFACTURING LLC
6603 femrite drive
madison WI 53718
Manufacturer (Section G)
MALLINCKRODT MANUFACTURING LLC
6603 femrite drive
madison WI 53718
Manufacturer Contact
mark wendelken
440 us rt 22 east
suite 302
bridgewater, NJ 08807
MDR Report Key25135541
Report Number3004531588-2026-00023
Device Sequence Number9325410
Product Code MRN
UDI-Device Identifier00867538000106
UDI-Public(01)00867538000106
Combination Product (Y/N)N
Initial Reporter StateNJ
Initial Reporter CountryUS
PMA/510(K) Number
K061901
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)N
Reporter Type Manufacturer
Report Source Health Professional,Company Representative
Initial Reporter Occupation Non-Healthcare Professional
Type of Report Initial
Report Date (Section B) 05/11/2026
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Model Number10007
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer04/20/2026
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 04/21/2026
Initial Report FDA Received Date05/11/2026
Was Device Evaluated by Manufacturer? (Y/N) Yes
Date Device Manufactured12/16/2015
Is the Device Labeled for Single Use? (Y/N) No
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Unknown
Patient Sequence Number1
Patient SexUnknown
-
-