Product complaint#: (b)(4).This is a combination product, and the event has been reviewed for both the suture and the triclosan.This report is being submitted pursuant to the provisions of 21 cfr, part 803, part 4 subpart b.This report may be based on information which has not been investigated or verified prior to the required reporting date.This report does not reflect a conclusion by ethicon, or its employees that the report constitutes an admission that the product, ethicon, or its employees caused or contributed to the potential event described in this report.If information is obtained that was not available for the initial report, a follow-up report will be filed as appropriate.D4: udi: as the lot number for the device involved in the event was not provided, the full udi is currently not available.Attempts have been made to retrieve the device.To date the device has not been returned.If the device or further details are received at a later date a supplemental medwatch will be sent.Additional information was provided: after the first set of product complaints towards the end of january, i went in and observed a day of cases.They were in the habit of double backing the suture and using up much of the stitch.I consulted with several folks and then suggested to the pa that not only is doubling back not necessary but was way too much material.She agreed, and in early february forward, was running the stitch per ifu.I didn't hear from them for a couple of months until the last few weeks, where the problem happened again.The most recent pc¿s did not have the migration or extrusion, but were suture abscesses developing along the length of the incision approximately 3 months post op.Additional information was provided: most recently, patients had superficial suture abscesses that were delayed and came on around the 3 months post-op.Superficial i & ds were performed on these wounds.Attempts are being made to obtain the following information.To date no response has been provided.If further details are received at a later date a supplemental medwatch will be sent.Did this issue contribute to any patient adverse event? was there any medical or surgical intervention performed (product removed; re-operation; re-suturing; re-closure; drainage)? if so, please specify.Was a prescription for steroids or antibiotics issued for the patient's recovery? if yes, please provide medication name, route and dose.What is the patient¿s current health status and condition? can you identify the lot number of the product involved? please provide the source or name and title of external person providing answers to follow-up (external person submitting answers to sales rep).Did the patient reported in (b)(6) require any medical or surgical intervention for the blood blister/suture abscess? if yes, please describe.What is the surgeon¿s experience with this stratafix suture? please provide the patient's demographic information including age, gender, weight, bmi at the time of index procedure.Were any concomitant procedures performed? on what tissue was the suture used? what was the tissue condition (normal, thin, calcified, fragile, diseased)? for the original intended closure, how were all layers closed? was the fixation loop secured to tissue at the initiation of suture use during the index procedure? was at least one reverse stitch performed prior to closure? what symptoms did the patient experience following the index surgical procedure? onset date? please describe any medical/surgical intervention required for this suture event including dates and results.Specifically, what was done during the washout? was a new suture/re-suturing performed during the washout? if yes, was that new suture used an ethicon suture? please confirm: did another abscess/blood blister form after the washout on (b)(6) 2026? if yes, was any medical or surgical intervention performed for that abscess/blood blister? were there any pre-existing signs/symptoms of active infection prior to this surgical procedure? did the patient receive any prophylactic antibiotics pre-, intra- or post-operation? were cultures and sensitivities performed? if so, please provide the results.Were any pre-op cleansing procedures changed recently? if yes, please describe did the operating surgeon observe any suture deficiency or anomaly before, during, after the suture placement or during any re-operation? other relevant patient history/concomitant medications? what is the physician¿s opinion as to the etiology of or contributing factors to this event? what is the patient's current status? lot number? will product be returned? if so, please provide the return date and tracking information.
|