EXACTECH, INC. ADVANCED PATELLA 32MM 3 PEG IMPLANT; PROSTHESIS, KNEE, PATELLOFEMOROTIBIAL, SEMI-CONSTRAINED, CEMENTED, POLYMER/METAL
|
Back to Search Results |
|
| Catalog Number |
200-07-32 |
| Medical Device Problem Code |
Naturally Worn (2988)
|
| Health Effect - Clinical Codes |
Pain (1994); Synovitis (2094); Swelling/ Edema (4577); Aseptic loosening (4883)
|
| Date of Event |
03/07/2023
|
|
Type of Reportable Event
|
Serious Injury
|
|
Additional Manufacturer Narrative
|
|
D10: 02-022-45-3525 - truliant tib fit tray cem sz 3.5f / 2.5t, (b)(6).The reported event was unable to be confirmed due to limited information received from the customer.No device was returned for evaluation; further, photographs and/or radiograph images were not provided for review.A review of complaint history determined that no further action is required as no trends were identified.The investigation results concluded that the reported event occurred due to polyethylene wear and femoral loosening as stated in the operative notes and clinical study documentation.The femoral loosening may have been the result of an insufficient bond between the femoral component and the bone.The extent and root cause of the reported polyethylene wear cannot be determined as the devices were not available for evaluation and images of the explanted devices and pre-revision radiographs were not provided.If any further information is obtained that would change or alter any information provided, a supplemental report will be filed accordingly.
|
| |
|
Event or Problem Description
|
|
As reported by the exactech truliant knee clinical study and operative notes, the patient underwent bilateral total knee replacement surgery.The patient had initially done well but started having increased pain and swelling.An infection workup was negative.Approximately 4 years and 4 months post the initial surgery; the patient¿s right knee was revised to non-exactech components due to suspected polyethylene wear and femoral component loosening.Per the operative notes, there was a typical synovitis with particulate debris and the synovial tissue in the medial and lateral gutters.There was brownish discoloration as well and looked gritty.Surgeon debrided this synovial tissue and sent a sample of the tissue for culture.There were no signs of purulence or infection.On gross inspection, there was no significant wear (to the tibial insert).There were some pitting changes in the articular surface, primarily medially and the femoral component was disimpacted without any difficulties as there was no attachment to the cement mantle.Additionally, there was gross damage to the patellar button.The patient was awakened from anesthesia and transferred to the recovery room in stable condition.
|
| |
|
Search Alerts/Recalls
|
|
|