• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: W. L. GORE & ASSOCIATES, INC. GORE® VIABAHN® ENDOPROSTHESIS WITH HEPARIN BIOACTIVE SURFACE; STENT, SUPERFICIAL FEMORAL ARTERY

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

W. L. GORE & ASSOCIATES, INC. GORE® VIABAHN® ENDOPROSTHESIS WITH HEPARIN BIOACTIVE SURFACE; STENT, SUPERFICIAL FEMORAL ARTERY Back to Search Results
Catalog Number VBHR090502A
Medical Device Problem Code Difficult or Delayed Activation (2577)
Health Effect - Clinical Code Foreign Body In Patient (2687)
Date of Event 04/18/2026
Type of Reportable Event Malfunction
Event or Problem Description
On (b)(6) 2026, the patient underwent tambe endovascular treatment for an arterial dissection utilizing multiple gore® viabahn® vbx balloon expandable endoprosthesis (vbx device) devices in the visceral vessels and a gore® tri-lumen catheter (tlc).A gore® viabahn® endoprosthesis with heparin bioactive surface (viabahn device) was intended to be implanted in the left renal artery, however, it was left implanted in the right innominate artery.It was reported the physician reached the left renal artery and pulled the deployment line all the way.However, the physician had difficulty visualizing if the viabahn endoprosthesis expanded properly under fluoroscopic imaging.The delivery catheter was then withdrawn and it wasn¿t until the physician was at the right innominate artery when they noticed the viabahn endoprosthesis did not deploy in the left renal artery.When being withdrawn, the viabahn device met resistance by getting caught on an unspecified material, causing the viabahn endoprosthesis to dislodge into the right innominate artery.The viabahn endoprosthesis did not cover any major branch vessels, and the right innominate artery still had proper blood flow.The viabahn endoprosthesis was left as endo trash and the procedure was completed by placing a new viabahn device in left renal artery.No harm to the patient was reported as a result of these adverse events with remainder of the procedure completed successfully and the patient¿s status at the end of the procedure was reported as stable.
 
Additional Manufacturer Narrative
Cbas® heparin surface incorporates carmeda heparin manufactured from heparin sodium api, which is covalently bound to the device surface and is essentially non-eluting.W.L.Gore & associates, inc.(gore) is submitting this report to comply with 21 c.F.R.Part 803, the medical device reporting regulation.This report is based upon information obtained by gore, which the company may not have been able to fully investigate or verify prior to the date the report was required by the fda.Blank fields present on this report include required fields and fields determined to be not applicable.Blank required fields indicate that the information was not provided, was deemed unavailable or was not applicable.This report does not constitute an admission or a conclusion by fda, gore, or its associates that the device, gore or its associates caused or contributed to the event described in the report.In particular, this report does not constitute a legal admission by anyone that the product described in this report has any defects or has malfunctioned, as defined from a legal standpoint.These words are included in the report and are fixed items for selection created by the fda, to categorize the type of event solely for the purpose of reporting pursuant to part 803.This statement should be included with any information or report disclosed to the public under the freedom of information act.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
GORE® VIABAHN® ENDOPROSTHESIS WITH HEPARIN BIOACTIVE SURFACE
Common Device Name
STENT, SUPERFICIAL FEMORAL ARTERY
Manufacturer (Section D)
W. L. GORE & ASSOCIATES, INC.
1505 n. fourth street
flagstaff AZ 86004
Manufacturer (Section G)
MEDICAL ECHO RIDGE B/P
3250 w. kiltie lane
flagstaff AZ 86005
Manufacturer Contact
vanessa rodriguez
1505 n. fourth street
flagstaff, AZ 86004
9285263030
MDR Report Key25193268
Report Number2017233-2026-07510
Device Sequence Number21354441
Product Code NIP
UDI-Device Identifier00733132645947
UDI-Public(01)00733132645947(17)281010
Combination Product (Y/N)Y
Initial Reporter StateCA
Initial Reporter CountryUS
PMA/510(K) Number
P040037
Number of Events Summarized1
Summary Report (Y/N)N
Device Implanted Year2026
Serviced by Third Party (Y/N)N
Reporter Type Manufacturer
Report Source Company Representative
Initial Reporter Occupation Physician
Type of Report Initial,Followup
Report Date (Section B) 06/29/2026
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Catalogue NumberVBHR090502A
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 04/18/2026
Supplement Date Received by Manufacturer06/29/2026
Initial Report FDA Received Date05/15/2026
Supplement Report FDA Received Date06/29/2026
Was Device Evaluated by Manufacturer? (Y/N) No
Date Device Manufactured10/12/2025
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Patient Age46 YR
Patient SexMale
-
-