Catalog Number SVP4-0.021
Medical Device Problem Code Deformation Due to Compressive Stress (2889)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 10/07/2024
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
This event was identified during internal quality system activities.Upon review, the manufacturer determined the event meets fda criteria for reporting.The report is being submitted to ensure accuracy and completeness of mdr files.This submission does not reflect a change in device performance or patient risk.The awareness date corresponds to when the manufacturer became aware of the event details.All information reasonably known to the manufacturer at this time has been included.During secondary review it was determined this event was reported under g8 number 3012276280-2026-00005 where the manufacturer number and name was inadvertently reported incorrectly.This report with g8 number is the correct report for the siege plug as it is manufactured in south jordan, utah.We will send a cancellation for the other report indicating this one is correct.The suspect device was returned for evaluation and the siege vascular plug met specification and was acceptable.The root cause was that the physician used a catheter that was not recommended in the labeling.This complaint will be used to trend for similar complaints.A search of the complaint database was performed and no similar complaints for this lot number were found.The device history record was reviewed, and no exception documents were found.
 
Event or Problem Description
The customer reported that the physician used a 6.5 inside a.035 bernstein.The siege coiled up on itself and kinked.This happened after giving the instructions that the siege had only been tested for microcatheter compatibility.There was no reported patient injury and a new device was used to complete the procedure.No additional information was provided.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
SIEGE
Common Device Name
DEVICE, VASCULAR, FOR PROMOTING EMBOLIZATION
Manufacturer (Section D)
MERIT MEDICAL SYSTEMS INC.
1600 merit parkway
south jordan UT 84095
Manufacturer (Section G)
MERIT MEDICAL SYSTEMS INC.
1600 merit parkway
south jordan UT 84095
Manufacturer Contact
adrian cole
1600 merit parkway
south jordan, UT 84095
8012084225
MDR Report Key25280134
Report Number1721504-2026-00066
Device Sequence Number9677779
Product Code KRD
UDI-Device Identifier00884450815922
UDI-Public00884450815922
Combination Product (Y/N)N
Initial Reporter StateCA
Initial Reporter CountryUS
PMA/510(K) Number
K240261
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)Unknown
Reporter Type Manufacturer
Report Source Health Professional,User Facility,Company Representative
Initial Reporter Occupation Other
Type of Report Initial
Report Date (Section B) 05/26/2026
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Catalogue NumberSVP4-0.021
Device Lot NumberH3029716
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer10/17/2024
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 10/08/2024
Initial Report FDA Received Date05/26/2026
Was Device Evaluated by Manufacturer? (Y/N) No
Date Device Manufactured08/19/2024
Usage of Device Unknown
Patient Sequence Number1
Patient SexUnknown
-
-