• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: MAQUET CRITICAL CARE AB SERVO-I UNIT BASE; VENTILATOR, CONTINUOUS, FACILITY USE

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

MAQUET CRITICAL CARE AB SERVO-I UNIT BASE; VENTILATOR, CONTINUOUS, FACILITY USE Back to Search Results
Model Number 6487800
Medical Device Problem Codes Contamination /Decontamination Problem (2895); Failure of Device to Self-Test (2937)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 05/21/2026
Type of Reportable Event Malfunction
Event or Problem Description
It was reported that the ventilator failed internal leakage test during pr-use check.Furthermore, the air gas module was contaminated with water.There was no patient involvement.Manufacture's ref.#: (b)(4).
 
Additional Manufacturer Narrative
The reported ventilator was investigated on-site by the distributor's field service engineer (fse).The fse found traces of liquid contamination inside air gas module.The device will be repaired by replacing the air gas module.The air gas module regulate the inspiratory gas flow and gas mixture.The liquid contamination in the air gas module as previous investigation has shown, had affected the delta pressure transducer on a printed circuit board inside the air gas module.The delta pressure transducer is part of the flow measuring in the gas module.The failure of the delta pressure transducer leads to inaccurate gas flow regulation which will be detected during pre-use check and alarms will be activated if the failure occurs during ventilation.According to the applicable user's manual, maximum levels of water (h2o leass than 7 g/m3) in the supplied gases to the ventilator must not be exceeded.The conclusion is that the device did not fail to meet its specification, as the most probable source of liquid contamination in the air gas module is a contaminated air gas from the hospital's central air gas system.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
SERVO-I UNIT BASE
Common Device Name
VENTILATOR, CONTINUOUS, FACILITY USE
Manufacturer (Section D)
MAQUET CRITICAL CARE AB
roentgenvagen 2
solna
Manufacturer (Section G)
MAQUET CRITICAL CARE AB
roentgenvagen 2
solna
Manufacturer Contact
caroline kabbabe
roentgenvagen 2
solna 
MDR Report Key25357474
Report Number8010042-2026-0000714
Device Sequence Number10654315
Product Code CBK
UDI-Device Identifier07325710000823
UDI-Public(01)07325710000823(11)161115
Combination Product (Y/N)N
Initial Reporter CountryIN
PMA/510(K) Number
K123149
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)Y
Reporter Type Manufacturer
Report Source Foreign,Distributor
Initial Reporter Occupation 505
Type of Report Initial
Report Date (Section B) 06/01/2026
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Model Number6487800
Was Device Available for Evaluation? No
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 05/21/2026
Initial Report FDA Received Date06/02/2026
Was Device Evaluated by Manufacturer? (Y/N) No
Date Device Manufactured11/15/2016
Is the Device Labeled for Single Use? (Y/N) No
Usage of Device Initial
Patient Sequence Number1
Patient SexUnknown
-
-