Investigation of this event is pending and a supplemental report will be sent upon its completion.Medtronic submits this report to comply with fda regulations 21 cfr parts 4 and 803.Medtronic has made reasonable efforts to provide as much relevant information as is available to the company as of the submission date of this report.This report does not constitute an admission or a conclusion by fda, medtronic, or its employees that the device, medtronic, or its employee caused or contributed to the event described in the report.Any required fields that are unpopulated are blank because the information is currently unknown or unavailable.Medtronic will submit a supplemental report if additional relevant information becomes known.
|
|
It was reported that the patient was admitted for an ischemic stroke and was treated with thrombolytic therapy.The stroke then became hemorrhagic after thrombolytics were administered, comfort care measures were initiated, and the patient expired.The ventricular assist device remains implanted.
|
|
A supplemental report is being submitted for investigation completion.Product event summary: the ventricular assist device (vad) (b)(6) was not returned for evaluation.This complaint is associated with a clinical adverse event.A review of the device history records was not performed as the reported event is not related to a manufacturing or servicing issue.Log file analysis could not be performed since log files were not available.The reported thrombus event could not be confirmed due to insufficient evidence.Based on the available information, the device may have caused or contributed to the reported event.Per the instructions for use, neurological dysfunction, thrombus and death are known potential complication associated with the implantation of a vad.Based on review of past adverse events for this patient, it was noted that the patient had a history of thrombus events.Possible clinical factors that may have contributed to this event include the patient¿s pre-existing history and related comorbidities, the progression of their underlying disease, issues related to the therapeutic use of anticoagulant and anti-platelet medications and the patient's complex post-operative course.There are possible patient, pharmacological and procedural factors that may have contributed to this event.Investigation of this event is completed and the file will be closed.If new information is received, the file will be re-opened and a supplemental will be submitted.Medtronic submits this report to comply with fda regulations 21 cfr parts 4 and 803.Medtronic has made reasonable efforts to provide as much relevant information as is available to the company as of the submission date of this report.This report does not constitute an admission or a conclusion by fda, medtronic, or its employees that the device, medtronic, or its employee caused or contributed to the event described in the report.Any required fields that are unpopulated are blank because the information is currently unknown or unavailable.Medtronic will submit a supplemental report if additional relevant information becomes known.
|