• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: ALCON RESEARCH, LLC SILIKON 1000 OIL; FLUID, INTRAOCULAR

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

ALCON RESEARCH, LLC SILIKON 1000 OIL; FLUID, INTRAOCULAR Back to Search Results
Catalog Number 8065601187
Medical Device Problem Code Product Quality Problem (1506)
Health Effect - Clinical Code Insufficient Information (4580)
Date of Event 01/02/2026
Type of Reportable Event Serious Injury
Event or Problem Description
A physician reported that after the post operative three months of the vitrectomy surgery, the tamponade oil in the patient right eye was emulsified.The silicone oil was removed from the patient eye.The patient was not hospitalized.There was no patient health impact reported.This report pertains to one of three reports from the same facility.
 
Additional Manufacturer Narrative
Additional information provided in sections h.6., and h.11.Photos of the customers eye were provided by the reporter, and a sample was not received at the investigation site for evaluation.Retention sample testing is not required based on assessment performed.A review of complaints reported against this batch/lot was performed.Two similar complaints were reported for the batch/lot under investigation.A non-conformance-based review of the batch/lot was performed and did not reveal any potential contributing factors to the reported complaint.A review of the manufacturing batch record was performed prior to product release to ensure that the product was manufactured in compliance with the product¿s acceptance criteria.Based on the assessment, the product met release criteria.Viscosity demonstrated a gradual increase over time; however, all results remained within established stability specifications throughout the product shelf life.No significant differences were observed between storage conditions (25°c vs.30°c).Observed trends, including increases in viscosity and d6 levels, are not considered to impact product quality or stability.Overall, oil meets stability requirements and remains suitable for its intended shelf life and distribution conditions.This oil was indicated for use as a prolonged retinal tamponade in selected cases of complicated retinal detachments where other interventions are not appropriate for patient management.Complicated retinal detachments or recurrent retinal detachments occur most commonly in eyes with proliferative vitreoretinopathy (pvr), proliferative diabetic retinopathy (pdr), cytomegalovirus (cmv) retinitis, giant tears, and following perforating injuries.The oil was also indicated for primary use in detachments due to acquired immune deficiency syndrome (aids), related cmv retinitis and other viral infections affecting the retina.The oil should be stored at room temperature, 15°-32°c (59°-89°f).A review of production information, complaint history, and service (as applicable) was carried out and did not reveal any potential contributing factors to the complaint.Based on the investigation, a failure of the device, labeling, or packaging to meet specifications could not be confirmed.As the root cause and its origin are inconclusive, further investigative or manufacturing actions are not warranted currently.Receipt of additional relevant information or supporting materials will prompt a re-evaluation of the complaint investigation.- solution quality issue ¿ unlikely; lab data for this lot was reviewed and was found to have met release criteria.The release results for viscosity are in the midrange of the specification.- nonconforming components¿ unlikely, incoming component inspection results indicate the components used was acceptable.- event related to surgical technique/dfu not followed ¿ no conclusion can be made regarding the contribution of surgical technique.Dfu states: an underfill may result in an ineffective inferior tamponade and an overfill may result in corneal abnormalities and elevated iop.- event related to consumer physiology ¿ no conclusion can be made regarding the contribution of unique consumer physiology as this factor is outside the control of the manufacturing facility.Dfu states: both emulsification and elevated iop (intraocular pressure) are known adverse reactions of oil.A comprehensive review was performed of the manufacturing for this lot including a review of the batch records, production processes, complaint history, finished product inspection results, as well as the product stability review.The review shows that the manufacturing process was in a state of control.Based on the acceptable mbr review and finished product inspection results, this product lot continues to be acceptable.The manufacturer internal reference number is: (b)(4).
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
SILIKON 1000 OIL
Common Device Name
FLUID, INTRAOCULAR
Manufacturer (Section D)
ALCON RESEARCH, LLC
6201 south freeway
fort worth TX 76134
Manufacturer (Section G)
ALCON RESEARCH, LLC
6201 south freeway
fort worth TX 76134
Manufacturer Contact
jonathan schlech
6201 south freeway
mail stop ab2-6
fort worth, TX 76134
8007579780
MDR Report Key25471925
Report Number1610287-2026-00030
Device Sequence Number21409112
Product Code LWL
UDI-Device Identifier00380656011873
UDI-Public(01)00380656011873(17)280531(11)250818(10)12X3F
Combination Product (Y/N)N
Initial Reporter StateOH
Initial Reporter CountryUS
PMA/510(K) Number
P950008
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source Health Professional,Company Representative
Initial Reporter Occupation Physician
Type of Report Initial
Report Date (Section B) 06/11/2026
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Operator of Device Health Professional
Device Catalogue Number8065601187
Device Lot Number12X3F
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Initial
Initial Date Received by Manufacturer 05/18/2026
Initial Report FDA Received Date06/11/2026
Date Device Manufactured08/18/2025
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Outcome Attributed to Adverse Event Required Intervention;
Patient Age64 YR
Patient SexMale
-
-