Model Number SC-2218-70
Medical Device Problem Code Unexpected Therapeutic Results (1631)
Health Effect - Clinical Code Pain (1994)
Date of Event 03/25/2026
Type of Reportable Event Serious Injury
Additional Manufacturer Narrative
Block b3: approximated based on the date the manufacturer became aware of the event.Additional suspect medical device component involved in the event: model number/catalog number: sc-2218-70 serial number: (b)(6).Batch/lot number: 7089952 model/catalog description: linear st lead kit 70 cm unique identifier (udi): (b)(4).
 
Event or Problem Description
It was reported that the patient experienced inadequate stimulation.The patient underwent spinal cord stimulator (scs) replacement procedure.
 
Event or Problem Description
It was reported that the patient experienced inadequate stimulation.The patient underwent spinal cord stimulator (scs) lead replacement procedure.Additional information was received that the patient was doing well postoperatively.All explanted device components were discarded and will not be returned.
 
Additional Manufacturer Narrative
This report is being submitted to correct the additional mfr narrative, in section h11, device manufacturers only.Block b3: approximated based on the date the manufacturer became aware of the event.Additional suspect medical device component involved in the event: model number/catalog number: sc-2218-70 serial number: (b)(6) batch/lot number: 7089952 model/catalog description: linear st lead kit 70 cm unique identifier (udi): (b)(4) investigation results: the devices were not returned for analysis; therefore, a technical analysis could not be performed.Device history record: it was confirmed these devices met manufacturing specification prior to distribution and there were no manufacturing deviations which could have contributed to the reported event.Labeling review: review of the instructions for use (ifu) confirmed there was relevant content and sufficient guidance with respect to the circumstances described within this complaint.No updates are required to the ifu as a result of this event.Investigation conclusion: based on a thorough review of the reported complaint, boston scientific has assigned an investigation conclusion code of cause not established.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
LINEAR? ST
Common Device Name
STIMULATOR, SPINAL-CORD, TOTALLY IMPLANTED FOR PAIN RELIEF
Manufacturer (Section D)
BOSTON SCIENTIFIC NEUROMODULATION CORPORATION
25155 rye canyon loop
valencia CA 91355
Manufacturer (Section G)
BOSTON SCIENTIFIC CORPORATION
road 698, lot no. 12
dorado PR 00646 -260
*   00646-2602
Manufacturer Contact
erik sherburne
25155 rye canyon loop
valencia, CA 91355
7632920920
MDR Report Key25526656
Report Number3006630150-2026-04176
Device Sequence Number16137562
Product Code LGW
UDI-Device Identifier08714729767749
UDI-Public(01)08714729767749(17)241218(10)7089541
Combination Product (Y/N)N
Initial Reporter StateIN
Initial Reporter CountryUS
PMA/510(K) Number
P030017
Number of Events Summarized1
Summary Report (Y/N)N
Device Implanted Year2023
Device Explanted Year2026
Serviced by Third Party (Y/N)Unknown
Reporter Type Manufacturer
Report Source Health Professional,Company Representative
Initial Reporter Occupation Physician
Type of Report Initial,Followup
Report Date (Section B) 07/13/2026
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Operator of Device Lay User/Patient
Device Expiration Date12/18/2024
Device Model NumberSC-2218-70
Device Catalogue NumberSC-2218-70
Device Lot Number7089541
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 05/21/2026
Supplement Date Received by Manufacturer06/17/2026
Initial Report FDA Received Date06/16/2026
Supplement Report FDA Received Date07/13/2026
Date Device Manufactured12/19/2022
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Outcome Attributed to Adverse Event Required Intervention;
Patient Age52 YR
Patient SexFemale
-
-