|
As reported by the field clinical specialist (fcs), approximately 6 years and 11 months post transfemoral tavr (transcatheter aortic valve replacement) procedure with a 23mm sapien 3 valve, the valve failed due to a severe paravalvular leak (pvl).The sapien valve was ballooned with a 26mm non-edwards device to relieve some of the pvl, but this was unsuccessful.In response, a second valve (26mm sapien 3 ultra) was implanted slightly deeper via valve-in-valve procedure, after which the pvl reduced to a mild degree.Additional information provided per valve clinical coordinator indicating there was mild pvl at initial tavr implant.The patient since presented with shortness of breath and a mean gradient of 6mmhg.The final patient outcome of the patient is reported as stable upon discharge.According to the provided medical records, transthoracic echocardiogram (tte) performed 4 days prior to revision noted a 26mm bioprosthetic valve that appears well seated with no rocking or aberrant motion.While there is no intravalvular regurgitation, there is moderate perivalvular regurgitation, the mean systolic gradient is 6mmhg, peak gradient is 9mmhg and the valve area is 2.6cm^2.
|
|
Per the instructions for use (ifu), paravalvular leak (pvl) is a known potential adverse event associated with bioprosthetic heart valves and the transcatheter valve replacement (tvr) procedure.Paravalvular leak refers to blood flowing through a channel between the structure of the implanted valve and the landing zone, as a result of a lack of appropriate sealing of the valve to the target site.Some pvl is not uncommon post-deployment.Many cases are mild to moderate, and either resolve over time or do not cause symptoms.Others may be more clinically significant and require intervention.The patient screening manual and the procedure didactic identify several procedural and anatomical factors which could contribute to pvl, including device malposition, inaccurate measurement of the landing zone, uneven distribution of calcium on the landing zone, bulky or severe calcification, an elliptical annulus shape, and valve under-sizing.The mechanism behind worsening or late pvl is not well understood but may be related to cardiac remodeling.Edwards extensively trains physicians before they are qualified to use the sapien transcatheter heart valves (all models).The device training manuals instructs the operator on proper imaging screening requirements, including the use of good quality echocardiography and/or computed tomography (ct) to appropriately measure the landing zone, assess the content and distribution of calcium, and other patient anatomical factors.Multiple imaging modalities should be considered during valve size selection.Contraindications, important considerations when assessing the valve, and choosing the proper transcatheter heart valve are also discussed.The device training manuals also instruct the operator on proper positioning and deployment of the valve, including patients screening and procedural considerations.Device preparation, approach, deployment, imaging, procedure-specific training manuals, and proctored procedures are also included.In this case, there was no allegation or indication a product malfunction contributed to this adverse event.Investigation results are inconclusive due to the limited information provided.A review of edwards lifesciences risk management documentation was performed for this case.The reported event is an anticipated risk of the transcatheter heart valve procedure, additional assessment of this adverse event is not required at this time.The ifu and training manuals have been reviewed and no inadequacies have been identified with regards to warnings, contraindications, and the directions/conditions for the successful use of the device.Complaint histories for all reported events are reviewed against trending control limits monthly, and any excursions above the control limits are assessed and documented as part of this monthly review.As such, neither a product risk assessment, nor corrective or preventative actions are required at this time.
|