U.S. Department of Health and Human Services

MAUDE Adverse Event Report: ZIMMER BIOMET, INC. NEXGEN ARTICULAR SURFACE SIZE EF 14 MM HEIGHT; PROSTHESIS, KNEE

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

ZIMMER BIOMET, INC. NEXGEN ARTICULAR SURFACE SIZE EF 14 MM HEIGHT; PROSTHESIS, KNEE Back to Search Results
Catalog Number 00596403214
Medical Device Problem Code Adverse Event Without Identified Device or Use Problem (2993)
Health Effect - Clinical Codes Cyst(s) (1800); Inflammation (1932); Pain (1994); Ambulation or Postural Difficulties (2544); Swelling/ Edema (4577); Medical device site infection (4845)
Type of Reportable Event Serious Injury
Additional Manufacturer Narrative
(b)(4).B3: onset of patient symptoms is reported to have occurred in (b)(6) 2025.D10: stemmed tibial component precoat size 3: catalog#00598003701, lot#j6828726; lps flex femoral component size e left: catalog#00596801551, lot#65117559.G2: foreign - event occurred in germany.Visual and dimensional evaluations of the product could not be performed as no product was returned nor were pictures provided.The product remains implanted.Device history record was reviewed and no discrepancies related to the reported event were found.The reported products were reviewed for compatibility and it was determined that the femoral implant and articular surface are not compatible.Regarding the reported infection, the root cause is considered not device related.All products manufactured followed appropriate standards, and the reported infection occurred > 90 days; therefore, implanted products are not identified as the source or contributing to the reported infection.Root cause was unable to be determined regarding the additional patient complications beyond infection; however, it was identified that the patient had non-compatible devices in situ.The implanted femoral and articular surface device combination is not approved/cleared for use and is not a legally marketed combination per the device instructions for use.The reported event was unable to be confirmed.If any further information is found which would change or alter any conclusions or information, a supplemental report will be filed accordingly.Zimmer biomet will continue to monitor for trends.
 
Event or Problem Description
It was reported that a patient underwent a total knee procedure.Approximately one (1) year and four (4) months post-implantation, the patient began to experience pain, swelling, and inflammation.Diagnostic imaging and punctures revealed fluid accumulation due to a ruptured baker's cyst however no evidence of loosening or other complications were present.The patient then began to experience difficulty ambulating with further increased pain and swelling after significant activity.Approximately ten (10) months post symptom onset, an additional diagnostic sample revealed infection in the implanted joint.Subsequent intervention as a result of the confirmed infection has not been reported and the devices remain implanted.All available information has been provided.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
NEXGEN ARTICULAR SURFACE SIZE EF 14 MM HEIGHT
Common Device Name
PROSTHESIS, KNEE
Manufacturer (Section D)
ZIMMER BIOMET, INC.
1800 w. center st.
warsaw IN 46580
Manufacturer (Section G)
ZIMMER BIOMET, INC.
1800 w. center st.
warsaw IN 46580
Manufacturer Contact
jennifer rapsavage
56 e. bell dr.
warsaw, IN 46582
5745260384
MDR Report Key25693090
Report Number0001822565-2026-02431
Device Sequence Number13179142
Product Code JWH
UDI-Device Identifier00889024634947
UDI-Public(01)00889024634947(17)280613(10)66082241
Combination Product (Y/N)N
Initial Reporter CountryGM
PMA/510(K) Number
K173057
Number of Events Summarized1
Summary Report (Y/N)N
Device Implanted Year2023
Serviced by Third Party (Y/N)N
Reporter Type Manufacturer
Report Source Foreign,Consumer
Initial Reporter Occupation Non-Healthcare Professional
Type of Report Initial
Report Date (Section B) 07/02/2026
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? Yes
Operator of Device Lay User/Patient
Device Catalogue Number00596403214
Device Lot Number66082241
Was Device Available for Evaluation? No
Was the Report Sent to FDA? No
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 06/18/2026
Initial Report FDA Received Date07/02/2026
Was Device Evaluated by Manufacturer? (Y/N) Yes
Date Device Manufactured06/15/2023
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Concomitant Medical Products
and Therapy/Usage Dates
SEE H11 NARRATIVE.
Outcome Attributed to Adverse Event Required Intervention;
Patient SexUnknown
-
-