MAUDE Adverse Event Report: FISHER & PAYKEL HEALTHCARE LTD ADULT DUAL HEATED EVAQUA BREATHING CIRCUIT; BZE

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

FISHER & PAYKEL HEALTHCARE LTD ADULT DUAL HEATED EVAQUA BREATHING CIRCUIT; BZE Back to Search Results
Model Number RT340
Device Problems Leak/Splash (1354); Device Damaged Prior to Use (2284)
Patient Problem No Patient Involvement (2645)
Event Date 06/03/2014
Event Type  malfunction  
Event Description
A hospital in (b)(6) reported via our distributor that they found a leak in the expiratory limb of an rt340 adult evaqua breathing circuit whilst testing it before use.This was found prior to patient use.
 
Manufacturer Narrative
(b)(4).Method: the complaint rt340 breathing circuit was returned to fisher & paykel healthcare (fph) in (b)(4) and was visually inspected.Results: visual inspection revealed a hole in the evaqua limb of the circuit about 66cm away from the patient end connector.A lot check could revealed one other similar complaint for lot number 131217.Conclusion: based on our visual inspection, the evaqua limb was most likely punctured or scratched with a blunt object.All rt340 breathing circuits are visually inspected and pressure tested for leaks before releasing for distribution.Any breathing circuit which fails is discarded.In addition, tube weighing and bond strength testing are performed every 15 minutes.If any faults are detected the whole batch is placed on hold for investigation.This suggests that the subject breathing circuit was damaged after it was released for distribution.The key difference between the evaqua breathing circuits and conventional breathing circuits is that the expiratory limb of the evaqua circuits such as the rt340 is composed of a thin, semi-permeable film specially designed to allow water vapour from expired ventilatory gas to pass through.The evaqua expiratory tube has a protective mesh which prevents damage to the walls of the tube, however the evaqua tubing can be more susceptible to damage than conventional circuits when exposed to rough handling.The user instructions that accompany the rt340 adult dual heated evaqua breathing circuit state the following: perform a pressure and leak test on the breathing system and check for occlusions before connecting to a patient.Set appropriate ventilator alarms.Fit only the supplied fisher & paykel healthcare circuit hanger with care to avoid circuit damage.Do not stretch or milk the tubing.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
ADULT DUAL HEATED EVAQUA BREATHING CIRCUIT
Type of Device
BZE
Manufacturer (Section D)
FISHER & PAYKEL HEALTHCARE LTD
15 maurice paykel place
east tamaki
auckland, 2013
NZ  2013
Manufacturer (Section G)
FISHER & PAYKEL HEALTHCARE LTD
15 maurice paykel place
east tamaki
auckland, 2013
NZ   2013
Manufacturer Contact
raymond yan
15365 barranca parkway
irvine, CA 92618-2216
9494534000
MDR Report Key3924476
MDR Text Key4665282
Report Number9611451-2014-00577
Device Sequence Number1
Product Code BZE
Combination Product (y/n)N
Reporter Country CodeKS
PMA/PMN Number
K983112
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type Foreign,Health Professional,User Facility,Distributor
Reporter Occupation Other
Type of Report Initial
Report Date 06/12/2014
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Model NumberRT340
Device Catalogue NumberRT340
Device Lot Number131217
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer07/01/2014
Is the Reporter a Health Professional? No
Initial Date Manufacturer Received 06/12/2014
Initial Date FDA Received07/09/2014
Was Device Evaluated by Manufacturer? Yes
Date Device Manufactured12/17/2013
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial
Patient Sequence Number1
-
-