Model Number VTICM5_12.1(-11.5/4.0)
Medical Device Problem Code Adverse Event Without Identified Device or Use Problem (2993)
Health Effect - Clinical Codes Intraocular Pressure Increased (1937); No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 03/26/2026
Type of Reportable Event Serious Injury
Event or Problem Description
The reporter indicated that following an implantable collamer lens (icl) implantation procedure, the patient experienced lens rotation and refractive surprise.The lens was repositioned.This did not resolve the problem.The lens was exchanged for a stronger power but same model and length lens.The problem was resolved.Cause of the event was reported as unknown.
 
Additional Manufacturer Narrative
H6 - rotation.H6 - work order search: no additional similar complaint type events within associated lots were found.Refractive surprise: each lens is subjected to a 100% assessment of the power (spherical and cylinder) and optical resolution during the manufacturing process in order to determine acceptability per the lens model and diopter.Secondary surgical intervention to remove/replace/reposition the lens is identified in the labeling as a known potential adverse event following icl implantation.Claim #(b)(4).
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
EVO/EVO+ VISIAN Implantable Collamer Lens (ICL)
Common Device Name
Phakic Toric Intraocular Lens
Manufacturer (Section D)
STAAR Surgical Company
1911 walker avenue
monrovia CA 91016
Manufacturer (Section G)
STAAR Sugical Company
1911 walker avenue
monrovia 91016
Manufacturer Contact
joselene muniz
1911 walker avenue
monrovia, CA 91016
MDR Report Key50002137
Report Number2023826-2026-01362
Device Sequence Number21488938
Product Code QCB
UDI-Device Identifier00840311306176
UDI-Public(01)00840311306176(11)250403(17)280331
Combination Product (Y/N)N
Initial Reporter CountrySN
PMA/510(K) Number
P030016
Number of Events Summarized1
Summary Report (Y/N)N
Device Implanted Year2026
Device Explanted Year2026
Serviced by Third Party (Y/N)N
Reporter Type Manufacturer
Report Source Foreign,Health Professional,Company Representative
Initial Reporter Occupation Physician
Type of Report Initial
Report Date (Section B) 07/22/2026
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Device Expiration Date03/31/2026
Device Model NumberVTICM5_12.1(-11.5/4.0)
Device Catalogue NumberVTICM5_12.1
Device Lot NumberN/A
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 07/21/2026
Initial Report FDA Received Date07/27/2026
Date Device Manufactured04/03/2025
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Concomitant Medical Products
and Therapy/Usage Dates
Cartridge Model-UNK, Lot#-UNK.; Injector Model-UNK,Lot#-UNK.; UNK-Model-UNK, Lot#-UNK.
Outcome Attributed to Adverse Event Required Intervention;
Patient SexMale
-
-