Alcon Laboratories Ireland Ltd. CLAREON PANOPTIX PRO Trifocal UV Absorbing IOL w/AutonoME Delivery System; Intraocular Lens Back to Search Results
Model Number PXCAT0
Medical Device Problem Code Adverse Event Without Identified Device or Use Problem (2993)
Health Effect - Clinical Codes Visual Impairment (2138); Visual Disturbances (2140)
Date of Event 02/11/2026
Type of Reportable Event Serious Injury
Event or Problem Description
A non health care professional reported that following an intraocular lens (iol) implant procedure, the patient had intolerable glare and halos at night.Clinical reason being mentioned as multifocality.The iol was explanted and exchanged with an unspecified atiol (advanced technology intraocular lens) in the secondary implant procedure.Additional information was requested and received, stating that in the surgeon's opinion, the product was the cause of the issue.There was no further impact to the patient.
 
Additional Manufacturer Narrative
A product was not returned for analysis.Complaint history and product history records were reviewed and documentation indicated the product met release criteria.Root cause has not been identified.The manufacturer internal reference number is: (b)(4).
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
CLAREON PANOPTIX PRO Trifocal UV Absorbing IOL w/AutonoME Delivery System
Common Device Name
Intraocular Lens
Manufacturer (Section D)
Alcon Laboratories Ireland Ltd.
cork business&technology park
model farm road
cork 00000
EI  00000
Manufacturer (Section G)
Alcon Laboratories Ireland Ltd.
cork business&technology park
model farm road
cork 00000
EI   00000
Manufacturer Contact
jonathan schlech
6201 south freeway
mail stop ab2-6
fort worth, TX 76134
+1(800)757-9780
MDR Report Key50019830
Report Number9612169-2026-01708
Device Sequence Number10551334
Product Code HQL
UDI-Device Identifier00380658490355
UDI-Public(01)00380658490355(17)301011(11)251013(10)26123135
Combination Product (Y/N)N
Initial Reporter StateFL
Initial Reporter CountryUS
PMA/510(K) Number
P190018
Number of Events Summarized1
Summary Report (Y/N)N
Device Implanted Year2026
Device Explanted Year2026
Reporter Type Manufacturer
Report Source Company Representative
Initial Reporter Occupation Non-Healthcare Professional
Type of Report Initial
Report Date (Section B) 07/24/2026
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Operator of Device Health Professional
Device Model NumberPXCAT0
Device Catalogue NumberPXCAT0.205
Device Lot Number26123135
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? No
Initial Date Received by Manufacturer 07/01/2026
Initial Report FDA Received Date07/27/2026
Date Device Manufactured10/13/2025
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Concomitant Medical Products
and Therapy/Usage Dates
Clareon Vivity Extended Vision UV Absorbing IOL; MONARCH III IOL Delivery System, Cartridge C; MONARCH III IOL Delivery System, Injector; PROVISC Ophthalmic ViscoSurgical Device
Outcome Attributed to Adverse Event Required Intervention;
Patient SexUnknown
-
-