Model Number PPDS2015
Medical Device Problem Code Adverse Event Without Identified Device or Use Problem (2993)
Health Effect - Clinical Codes Abscess (1690); Adhesion(s) (1695); Unspecified Infection (1930); Inflammation (1932); Necrosis (1971); Pain (1994); Sepsis (2067); Hernia (2240); Unspecified Tissue Injury (4559)
Type of Reportable Event Death
Event or Problem Description
The patient's attorney alleged a deficiency against the device.The product was used for therapeutic treatment of a ventral hernia.It was reported that after implant, the patient experienced pain, infection, recurrence, inflammation, adhesions, abscess, sepsis, necrotic fascia and death.Post-operative patient treatment included wound vac, excisional debridement of anterior abdominal wall fascia, pulse lavage of abdominal wall, incision and drainage of abscess, mesh removal, hernia repair with new mesh and hospitalization.Information received indicates the patient is deceased.No information was provided regarding the circumstances of expiration.
 
Additional Manufacturer Narrative
Medtronic submits this report to comply with fda regulations 21 cfr parts 4 and 803.Medtronic has made reasonable efforts to provide as much relevant information as is available to the company as of the submission date of this report.This report does not constitute an admission or a conclusion by fda, medtronic, or its employees that the device, medtronic, or its employee caused or contributed to the event described in the report.Any required fields that are unpopulated are blank because the information is currently unknown or unavailable.Medtronic will submit a supplemental report if additional relevant information becomes known.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
Parietene DS
Common Device Name
MESH, SURGICAL, POLYMERIC
Manufacturer (Section D)
SOFRADIM PRODUCTION SAS
116 avenue du formans
trevoux 01600
FR  01600
Manufacturer (Section G)
SOFRADIM PRODUCTION SAS
116 avenue du formans
trevoux 01600
FR   01600
Manufacturer Contact
mike bocchino
8200 coral sea st ne
mounds view, MN 55112--439
+1(800)646-4633
MDR Report Key50038121
Report Number9615742-2026-00723
Device Sequence Number18588967
Product Code FTL
UDI-Device Identifier10884521553477
UDI-Public(01)10884521553477(17)210630(10)RTG2618X
Combination Product (Y/N)N
Initial Reporter StateMA
Initial Reporter CountryUS
PMA/510(K) Number
K163212
Number of Events Summarized1
Summary Report (Y/N)N
Device Implanted Year2020
Device Explanted Year2020
Serviced by Third Party (Y/N)N
Reporter Type Manufacturer
Report Source Consumer
Initial Reporter Occupation Non-Healthcare Professional
Type of Report Initial
Report Date (Section B) 07/27/2026
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Operator of Device Health Professional
Device Expiration Date06/30/2021
Device Model NumberPPDS2015
Device Catalogue NumberPPDS2015
Device Lot NumberRTG2618X
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? No
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 07/22/2026
Initial Report FDA Received Date07/27/2026
Date Device Manufactured07/29/2019
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
Outcome Attributed to Adverse Event Hospitalization; Required Intervention; Death; Life Threatening;
Patient SexFemale
Patient Weight190 LB
-
-