| Model Number |
M00505530 |
| Medical Device Problem Codes |
Failure to Cut (2587); Activation Failure (3270)
|
| Health Effect - Clinical Code |
No Clinical Signs, Symptoms or Conditions (4582)
|
| Date of Event |
06/01/2026
|
|
Type of Reportable Event
|
Serious Injury
|
|
Event or Problem Description
|
|
It was reported to boston scientific that an overstitch suture cinch was used in a procedure performed on (b)(6) 2026.During the procedure, the device exhibited a condition where the cinch was being deployed, and it did not release from tissue.The physician attempted to "crunch" the handle, but the wire mechanism was bent within the handle.The cinch should have severed the suture and released from tissue.The procedure was completed after an extended time with another product of the same model.The patient outcome following the procedure is currently unknown, and there was no report about patient complications as a result of this event.
|
| |
|
Event or Problem Description
|
|
It was reported to boston scientific that an overstitch suture cinch was used in a procedure performed on (b)(6) 2026.During the procedure, the device exhibited a condition where the cinch was being deployed, and it did not release from tissue.The physician attempted to "crunch" the handle, but the wire mechanism was bent within the handle.The cinch should have severed the suture and released from tissue.The procedure was completed after an extended time with another product of the same model.The patient outcome following the procedure is currently unknown, and there was no report about patient complications as a result of this event.
|
| |
|
Additional Manufacturer Narrative
|
|
Block h6:
device code a050702 is being used to capture the reportable event of cinch failure to cut.Device code a150101 is being used to capture the reportable event of cinch failure to deploy.Imdrf code f2301 is being used to capture the reportable event of additional device required.In july 2026, boston scientific initiated a voluntary product removal associated with specific lots of the overstitch suture cinch (ref.(b)(4)).The referenced device was in scope of this product removal.Block h11: device evaluation
the device was not returned for analysis; therefore, a technical analysis could not be performed.Good faith effort attempts were
made to try and retrieve the device; however, device availability information was not available per the account.A review of the device history record (dhr) was performed.The review of the dhr identified that there were no process related non-conformances, scrap, or rework performed during the production that could explain the event.The reviews ensure each device meets specification prior to release for use.There is no indication the device manufacturing process contributed to the reported complaint.A similar complaint review was completed.There were no emerging trends identified that warrant further action.Based on a thorough review of the reported complaint, boston scientific has assigned an investigation conclusion code of cause not established.
|
| |
|
Additional Manufacturer Narrative
|
|
Block h6:
device code a050702 is being used to capture the reportable event of cinch failure to cut.Device code a150101 is being used to capture the reportable event of cinch failure to deploy.Imdrf code f2301 is being used to capture the reportable event of additional device required.In july 2026, boston scientific initiated a voluntary product removal associated with specific lots of the overstitch suture cinch (ref.(b)(4)).The referenced device was in scope of this product removal.
|
| |
|