• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: INTUITIVE SURGICAL, INC EndoWrist SP; CADIERE FORCEPS

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

INTUITIVE SURGICAL, INC EndoWrist SP; CADIERE FORCEPS Back to Search Results
Model Number 430009-62
Medical Device Problem Code Unintended System Motion (1430)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 07/02/2026
Type of Reportable Event Malfunction
Event or Problem Description
Refer to h11 for follow-up information.
 
Additional Manufacturer Narrative
Intuitive surgical, inc.(isi) did receive the cadiere forceps.Failure analysis confirmed and replicated the customer complaint.Failure analysis found the primary finding of the instrument roll gear broken to be related to the customer reported complaint.The cadiere forceps instrument was found to have a broken idler roll gear.The cadiere forceps housing was removed, and a piece of broken roll gear was found inside the housing.During a manual articulation of the inputs, the hard stop was not felt.It was noted that the broken gear prevented the main tube from articulating.The instrument failed to move intuitively during functional testing on the in-house system due to the broken roll gear.The instrument exhibited unintuitive motion due to the broken idler gear.The instrument was installed on an in-house system and driven.When placed on the in-house system, it was observed that the main tube did not rotate when commanded with the manual tool manipulator (mtm) on the surgeon side cart (ssc).With the instrument's wrist and joggle joint bent and commanding the instrument to roll, the instrument distal end would move in a circle, which appeared to be an unintuitive motion, as the circular motion was unexpected; the expected motion was for the distal end of the instrument to stay in a consistent location and only spin and roll.Additionally, in certain orientations over the ran of the roll direction, the instrument's distal tip moved opposite to what was commanded by the mtm.This behavior was observed in the roll direction and presented on all three installs, indicating a misalignment of the coordinate frames during the engagement sequence.The probable root cause is attributed to excessive user-applied mechanical loading beyond normal operating conditions, resulting in a fractured idler roll gear within the roll drive train.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
EndoWrist SP
Common Device Name
CADIERE FORCEPS
Manufacturer (Section D)
INTUITIVE SURGICAL, INC
3410 central expressway
santa clara CA 95051
Manufacturer (Section G)
INTUITIVE SURGICAL, INC
3410 central expressway
santa clara CA 95051
Manufacturer Contact
izabel nielson
3410 central expressway
santa clara, CA 95051
+1(408)523-2100
MDR Report Key50063618
Report Number2955842-2026-33769
Device Sequence Number10745982
Product Code NAY
UDI-Device Identifier00886874115213
UDI-Public(01)00886874115213(10)K10250320
Combination Product (Y/N)N
Initial Reporter CountryFR
PMA/510(K) Number
K182371
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source Other,Foreign
Initial Reporter Occupation Non-Healthcare Professional
Remedial Action Other
Type of Report Initial,Followup
Report Date (Section B) 09/23/2026
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Model Number430009-62
Device Catalogue Number430009
Device Lot NumberK10250320 0022
Was Device Available for Evaluation? Yes
Date Returned to Manufacturer08/27/2026
Is the Reporter a Health Professional? No
Initial Date Received by Manufacturer 07/06/2026
Supplement Date Received by Manufacturer08/31/2026
Initial Report FDA Received Date07/28/2026
Supplement Report FDA Received Date09/23/2026
Was Device Evaluated by Manufacturer? (Y/N) Yes
Date Device Manufactured03/20/2025
Is the Device Labeled for Single Use? (Y/N) No
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
If action reported to FDA under 21 USC 360i(g), list
FDA-assigned Recall Number or include a statement
N/A
Patient Sequence Number1
Patient SexUnknown
-
-