| Model Number |
3320 |
| Medical Device Problem Code |
Adverse Event Without Identified Device or Use Problem (2993)
|
| Health Effect - Clinical Codes |
Bradycardia (1751); Cardiac Arrest (1762); Low Blood Pressure/ Hypotension (1914); Tachycardia (2095); Ventricular Fibrillation (2130); Diminished Pulse Pressure (2606); Reduced Blood Flow (4598)
|
| Date of Event |
07/23/2026
|
|
Type of Reportable Event
|
Death
|
|
Event or Problem Description
|
|
It was reported that the patient died.It was reported that the patient presented with severe chest pain.A rotalink advancer, 1.25 mm rotalink burr and rotawire drive were selected for treatment of the left circumflex (lcx) and left main (lm) arteries.Following rotablation, slow coronary flow was observed.Medications were administered to manage the patients condition.The patients blood pressure progressively declined and the patient experienced cardiac arrest.Direct current defibrillation and cardiopulmonary resuscitation were performed.Despite all efforts, there was no return of spontaneous circulation, no recordable pulse or blood pressure.The patient was declared dead.The official cause of death was slow flow and bradycardia.
|
| |
|
Event or Problem Description
|
|
It was reported that the patient died.It was reported that the patient presented with severe chest pain.A rotalink advancer, 1.25 mm rotalink burr and rotawire drive were selected for treatment of the left circumflex (lcx) and left main (lm) arteries.Following rotablation, slow coronary flow was observed.Medications were administered to manage the patients condition.The patients blood pressure progressively declined and the patient experienced cardiac arrest.Direct current defibrillation and cardiopulmonary resuscitation were performed.Despite all efforts, there was no return of spontaneous circulation, no recordable pulse or blood pressure.The patient was declared dead.The official cause of death was slow flow and bradycardia.It was further reported that the patient also presented with shortness of breath, dyspnea and chest heaviness.Injections of adrenaline, atropine, calcium gluconate 10 ml and amiodarone 150 mg were administered during the procedure.Intra-aortic balloon pump (iabp) and
temporary pacemaker implantation (tpi) support was also provided.Patient was shifted to the critical care unit and place on mechanical ventilation.The patient experienced ventricular tachycardia and ventricular fibrillation.Hypotension and cardiac arrest were also noted as causes of death.
|
| |
|
Additional Manufacturer Narrative
|
|
Good faith effort attempts were made to try and retrieve additional details regarding the reported event, but further information was unable to be obtained.
|
| |
|
Search Alerts/Recalls
|