Alcon Laboratories Ireland Ltd. Clareon Toric Aspheric Hydrophobic Acrylic IOL with AutonoME Delivery System; Lens, Intraocular, Toric Optics Back to Search Results
Model Number CNA0T5
Medical Device Problem Codes Failure to Deliver (2338); Activation Failure (3270)
Health Effect - Clinical Code Insufficient Information (4580)
Date of Event 06/01/2026
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
Additional information was provided in d.9., h.3., h.6.And h.11.The product was returned for analysis and the reported complaint was observed.The device was returned loose inside the product carton.The lock-out assembly has been removed.Viscoelastic is observed in the device.The lens is present in the lens bay.The lever is moving freely and the plunger is not advancing.The device is taken apart for further evaluation.The canister is fully punctured.Lubricant is observed on the canister neck.No damage observed to o-rings.The device was reloaded and was reactivated with a new canister.The failure mode could not be replicated; the device activated with no issues.The root cause for the reported complaint is deemed to be manufacturing related (the faulty sub-assembly is supplied by company's vendor in (b)(6)).The product did not meet specifications.The plunger is not advancing when the lever is pressed.Based on the results from company manufacturing batch record, the products met release criteria.Investigation has been completed based on current information.The vendor has been notified of this complaint (see attached email).Based on our trend analysis there are no adverse trends identified for this complaint and based on these findings the residual risk remains at an acceptable level.The manufacturer internal reference number is: (b)(4).
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
Clareon Toric Aspheric Hydrophobic Acrylic IOL with AutonoME Delivery System
Common Device Name
Lens, Intraocular, Toric Optics
Manufacturer (Section D)
Alcon Laboratories Ireland Ltd.
cork business&technology park
model farm road
cork 00000
EI  00000
Manufacturer (Section G)
Alcon Laboratories Ireland Ltd.
cork business&technology park
model farm road
cork 00000
EI   00000
Manufacturer Contact
jonathan schlech
6201 south freeway
mail stop ab2-6
fort worth, TX 76134
+1(800)757-9780
MDR Report Key50085270
Report Number9612169-2026-01730
Device Sequence Number13219851
Product Code MJP
UDI-Device Identifier00380652399913
UDI-Public(01)00380652399913(17)290310(11)250312(10)26003459
Combination Product (Y/N)N
Initial Reporter CountryUS
PMA/510(K) Number
P190018
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source Foreign,Health Professional,Company Representative
Initial Reporter Occupation Other Health Care Professional
Type of Report Initial,Followup
Report Date (Section B) 09/29/2026
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Model NumberCNA0T5
Device Lot Number26003459
Was Device Available for Evaluation? Yes
Date Returned to Manufacturer09/01/2026
Is the Reporter a Health Professional? No
Initial Date Received by Manufacturer 07/06/2026
Supplement Date Received by Manufacturer09/07/2026
Initial Report FDA Received Date07/30/2026
Supplement Report FDA Received Date09/29/2026
Was Device Evaluated by Manufacturer? (Y/N) Yes
Date Device Manufactured03/12/2025
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
Yes
Usage of Device Initial
Patient Sequence Number1
Patient SexUnknown
-
-