W. L. Gore & Associates, Inc. GORE® DrySeal Flex Introducer Sheath; Introducer, Catheter
|
Back to Search Results |
|
| Catalog Number |
DSF2233 |
| Medical Device Problem Code |
Difficult to Advance (2920)
|
| Health Effect - Clinical Code |
Pseudoaneurysm (2605)
|
| Date of Event |
07/10/2026
|
|
Type of Reportable Event
|
Serious Injury
|
|
Event or Problem Description
|
|
It was reported to gore that, on (b)(6)2 026, the patient underwent zone 2 endovascular treatment for a thoracic aortic aneurysm using the gore® tag® thoracic branch endoprostheses and gore® tag® conformable thoracic stent graft with active control system.The gore® dryseal flex introducer sheath and gore® molding & occlusion balloon catheter were also used as accessories.A 22fr sheath was inserted via the right common femoral artery; however, resistance was encountered at the right external iliac artery, preventing further advancement.Angioplasty of the common iliac artery and external iliac artery was performed using a pta balloon, and sheath insertion was attempted again.Despite vessel dilation, the sheath could not be advanced beyond the right common iliac artery.Therefore, each device was advanced individually without the sheath.Subsequently, the ctag and the aortic component were deployed, followed by deployment of the side branch component in the left subclavian artery.Balloon dilation was then performed using the mob balloon catheter.Access angiography demonstrated suspected pseudoaneurysm at the proximal portion of the right common iliac artery.However, no additional intervention was performed, and the procedure was completed with observation and follow-up planned.The patient tolerated the procedure.
|
| |
|
Additional Manufacturer Narrative
|
|
A1: no patient specific details have been provided.Therefore, the patient initials reflect the w.L.Gore internal case number.W.L.Gore & associates, inc.(gore) is submitting this report to comply with 21 c.F.R.Part 803, the medical device reporting regulation.This report is based upon information obtained by gore, which the company may not have been able to fully investigate or verify prior to the date the report was required by the fda.Blank fields present on this report include required fields and fields determined to be not applicable.Blank required fields indicate that the information was not provided, was deemed unavailable or was not applicable.This report does not constitute an admission or a conclusion by fda, gore, or its associates that the device, gore or its associates caused or contributed to the event described in the report.In particular, this report does not constitute a legal admission by anyone that the product described in this report has any defects or has malfunctioned, as defined from a legal standpoint.These words are included in the report and are fixed items for selection created by the fda, to categorize the type of event solely for the purpose of reporting pursuant to part 803.This statement should be included with any information or report disclosed to the public under the freedom of information act.
|
| |
|
Search Alerts/Recalls
|
|
|