U.S. Department of Health and Human Services

MAUDE Adverse Event Report: W. L. Gore & Associates, Inc. GORE® Molding & Occlusion Balloon Catheter; Catheter, Intravascular Occluding, Temporary

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

W. L. Gore & Associates, Inc. GORE® Molding & Occlusion Balloon Catheter; Catheter, Intravascular Occluding, Temporary Back to Search Results
Catalog Number MOB37
Medical Device Problem Code Adverse Event Without Identified Device or Use Problem (2993)
Health Effect - Clinical Code Pseudoaneurysm (2605)
Date of Event 07/10/2026
Type of Reportable Event Serious Injury
Event or Problem Description
It was reported to gore that, on (b)(6)2026, the patient underwent zone 2 endovascular treatment for a thoracic aortic aneurysm using the gore® tag® thoracic branch endoprostheses and gore® tag® conformable thoracic stent graft with active control system.The gore® dryseal flex introducer sheath and gore® molding & occlusion balloon catheter were also used as accessories.A 22fr sheath was inserted via the right common femoral artery; however, resistance was encountered at the right external iliac artery, preventing further advancement.Angioplasty of the common iliac artery and external iliac artery was performed using a pta balloon, and sheath insertion was attempted again.Despite vessel dilation, the sheath could not be advanced beyond the right common iliac artery.Therefore, each device was advanced individually without the sheath.Subsequently, the ctag and the aortic component were deployed, followed by deployment of the side branch component in the left subclavian artery.Balloon dilation was then performed using the mob balloon catheter.Access angiography demonstrated suspected pseudoaneurysm at the proximal portion of the right common iliac artery.However, no additional intervention was performed, and the procedure was completed with observation and follow-up planned.The patient tolerated the procedure.
 
Additional Manufacturer Narrative
A1: no patient specific details have been provided.Therefore, the patient initials reflect the w.L.Gore internal case number.H6: a review of the manufacturing records for the device verified that the lot met all pre-release specifications.W.L.Gore & associates, inc.(gore) is submitting this report to comply with 21 c.F.R.Part 803, the medical device reporting regulation.This report is based upon information obtained by gore, which the company may not have been able to fully investigate or verify prior to the date the report was required by the fda.Blank fields present on this report include required fields and fields determined to be not applicable.Blank required fields indicate that the information was not provided, was deemed unavailable or was not applicable.This report does not constitute an admission or a conclusion by fda, gore, or its associates that the device, gore or its associates caused or contributed to the event described in the report.In particular, this report does not constitute a legal admission by anyone that the product described in this report has any defects or has malfunctioned, as defined from a legal standpoint.These words are included in the report and are fixed items for selection created by the fda, to categorize the type of event solely for the purpose of reporting pursuant to part 803.This statement should be included with any information or report disclosed to the public under the freedom of information act.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
GORE® Molding & Occlusion Balloon Catheter
Common Device Name
Catheter, Intravascular Occluding, Temporary
Manufacturer (Section D)
W. L. Gore & Associates, Inc.
1505 n. fourth street
flagstaff AZ 86004
Manufacturer (Section G)
Medical Phoenix 1 B/P
32360 n. north valley parkway
phoenix AZ 85085
Manufacturer Contact
eimi ueda
1505 n. fourth street
flagstaff, AZ 86004
+1(928)526-3030
MDR Report Key50085840
Report Number3007284313-2026-04965
Device Sequence Number9816322
Product Code MJN
UDI-Device Identifier00733132639489
UDI-Public(01)00733132639489(17)290224
Combination Product (Y/N)N
Initial Reporter CountryJA
PMA/510(K) Number
K172567
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)N
Reporter Type Manufacturer
Report Source Foreign,Company Representative
Initial Reporter Occupation Physician
Type of Report Initial
Report Date (Section B) 07/30/2026
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Operator of Device Health Professional
Device Catalogue NumberMOB37
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 07/10/2026
Initial Report FDA Received Date07/30/2026
Was Device Evaluated by Manufacturer? (Y/N) No
Date Device Manufactured02/26/2026
Is the Device Labeled for Single Use? (Y/N) Yes
Usage of Device Initial
Patient Sequence Number1
Outcome Attributed to Adverse Event Other;
Patient SexUnknown
-
-