It was reported that a patient underwent an unknown procedure on (b)(6) 2026 and suture was used.During the procedure, 1.4 cm of needle broke off during incision closure.The patient is scheduled for removal outpatient on (b)(6) 2026.There was no adverse outcomes such as pain, fever, anxiety, etc.No surgical delay was reported.Additional information was requested.
|
|
Product complaint # (b)(4)
this report is being submitted pursuant to the provisions of 21 cfr, part 803.This report may be based on information which has not been investigated or verified prior to the required reporting date.This report does not reflect a conclusion by ethicon inc, or its employees that the report constitutes an admission that the product, ethicon inc or its employees caused or contributed to the potential event described in this report.If information is obtained that was not available for the initial report, a follow-up report will be filed as appropriate.D4: udi: the expiration date is currently not available.Therefore, the full udi is currently not available.To date the device has not been returned.If the device or further details are received at a later date a supplemental medwatch will be sent.Attempts are being made to obtain the following information.To date no response has been provided.If further details are received at a later date a supplemental medwatch will be sent.Please provide the patient's demographic information including age, gender, weight, bmi at the time of index procedure.Name of index surgical procedure?
the diagnosis and indication for the index surgical procedure?
were any concomitant procedures performed?
what was the initial approach for the index surgical procedure? (open, laparoscopic or other)?
on what tissue was the suture used?
what was the tissue condition (normal, thin, calcified, fragile, diseased)?
what instruments were used to grasp the needle?
where was the needle grasped during use?
were x-rays performed to localize the needle fragment?
what was the size of the needle used?
where did the needle break (tip, middle, swage area)?
does the piece/device remain retained in the patient's tissue?
if the piece(s) were retained, where are they located/in what structure?
if retained, is the patient still scheduled for removal of the needle piece on (b)(6)2026?
please describe any medical/surgical intervention required for this suture event including dates and results.Did the operating surgeon observe any suture deficiency or anomaly before, during, after the suture placement or during any re-operation?
other relevant patient history/concomitant medications?
what is the physician¿s opinion as to the etiology of or contributing factors to this event?
what is the patient's current status?.
|