Model Number OM-10000
Medical Device Problem Code Mechanical Problem (1384)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 06/25/2026
Type of Reportable Event Malfunction
Event or Problem Description
N/a.
 
Additional Manufacturer Narrative
(b)(4).Updated sections: b4,g3,g6,h2,h3,h6,h11 the device was returned to the factory for evaluation on july 22, 2026, and the investigation was conducted on august 19, 2026.A visual inspection identified signs of clinical use and evidence of blood.No visual defects were observed on the intact returned device.The device was securely assembled onto a reference retractor blade by sliding the stabilizer base onto the rail and engaging the locking lever.The knob was evaluated for its ability to tighten the flexlink arm while the locking lever was in both the locked and unlocked positions.The flexlink arm could not be secured when the knob was turned clockwise.The knob continued to spin without tightening the arm.The device was disassembled to determine the cause of the flexlink arm not tightening.The fins of the acme nut were intact and made adequate contact with the knob.However, the external threads of the acme screw were not engaging with the internal threads of the acme nut.This condition explains why the knob continued to spin without tightening the flexlink arm.Lubricant was observed between the threads and within the acme screw.The presence of lubricant is expected because it is applied during assembly in accordance with work instruction, knob assembly.However, the lubricant exhibited a change in viscosity and had solidified on the surfaces of the acme screw and acme nut.Conclusion: based on the returned condition of the device and the evaluation results, the reported failure, ¿mechanical problem,¿ was confirmed.The most probable root cause was a change in the lubricant¿s viscosity and its solidification on the surfaces of the acme screw and acme nut.This condition prevented proper thread engagement, causing the knob to spin without tightening the flexlink arm.Nc-way-2026-021 was initiated to investigate this most probable root cause.The lot #3000552613 history record review was completed.There were no ncmrs, rework, or deviations documented for the reported lot number.Based on the dhr/lhr review results, it was determined that there is no relation between the batch manufacturing process and the reported failure.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
Acrobat-i Stabilizer
Common Device Name
Stabilizer, Heart
Manufacturer (Section D)
Maquet Cardiovascular LLC
45 barbour pond drive
wayne NJ 07470
Manufacturer (Section G)
Maquet Cardiovascular LLC
45 barbour pond drive
wayne NJ 07470
Manufacturer Contact
arelean guzman
45 barbour pond drive
wayne, NJ 07470
MDR Report Key50138017
Report Number2242352-2026-0000655
Device Sequence Number18813260
Product Code MWS
UDI-Device Identifier00607567700581
UDI-Public(01)00607567700581(10)3000552613(17)280415
Combination Product (Y/N)N
Initial Reporter StateAZ
Initial Reporter CountryUS
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)Y
Reporter Type Manufacturer
Report Source Health Professional,User Facility,Company Representative
Initial Reporter Occupation Nurse
Type of Report Initial,Followup
Report Date (Section B) 08/04/2026
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Model NumberOM-10000
Device Catalogue NumberOM-10000
Device Lot Number3000552613
Was Device Available for Evaluation? Yes
Date Returned to Manufacturer07/22/2026
Is the Reporter a Health Professional? No
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 07/15/2026
Supplement Date Received by Manufacturer09/22/2026
Initial Report FDA Received Date08/05/2026
Supplement Report FDA Received Date09/22/2026
Was Device Evaluated by Manufacturer? (Y/N) Yes
Date Device Manufactured04/16/2026
Is the Device Labeled for Single Use? (Y/N) Yes
Usage of Device Initial
Patient Sequence Number1
Patient Age81 YR
Patient SexFemale
Patient Weight189 LB
-
-