| Model Number |
72404237 |
| Medical Device Problem Codes |
Inflation Problem (1310); Mechanical Problem (1384); Malposition of Device (2616); Human-Device Interface Problem (2949)
|
| Health Effect - Clinical Code |
No Clinical Signs, Symptoms or Conditions (4582)
|
| Date of Event |
07/10/2026
|
|
Type of Reportable Event
|
Serious Injury
|
|
Event or Problem Description
|
|
It was reported that the patient implanted with an inflatable penile prosthesis (ipp) experienced difficulty operating the pump and inadequate inflation of the device.A revision procedure was performed, during which the existing pump was explanted and replaced with a tenacio pump.The physician suspected that the reservoir placement and pump location may have contributed to the reported issue.The age of the device was also considered a contributing factor.No patient complications were reported.
|
| |
|
Event or Problem Description
|
|
It was reported that the patient implanted with this inflatable penile prosthesis (ipp) experienced difficulty operating the pump and was dissatisfied.As a result, a surgical revision procedure was performed to replace with tenacio pump.No patient complications were reported.
|
| |
|
Additional Manufacturer Narrative
|
|
Correction to field b1: adverse event/product problem.Model number/catalog number: 72404155.Serial number: n/a.Batch/lot number: 1100319281.Model/catalog description: reservoir 65 ml pc/iz.Unique identifier (udi) #: (b)(4).The device is not available for analysis; therefore, no physical analysis of the product could be performed.The reported device performance allegation cannot be confirmed.The device history record (dhr) review confirmed that the device met all material, assembly and performance specifications.A review of the device instructions for use (ifu) was completed and did not reveal any evidence of device misuse, off label use, or failure to follow instructions.A risk review was completed and confirmed that the events of mechanical malfunction/revision due to mechanical malfunction and patient dissatisfaction (with length, ability to use and nonspecific reasons) were defined in the product risk documentation.This event type has been accounted for during analysis to support acceptable risk benefit for the product.Based on the information available the cause that contributed to the reported event cannot be established.Therefore, a conclusion code of cause not established was assigned to this investigation.
|
| |
|
Additional Manufacturer Narrative
|
|
Model number/catalog number: 72404155
serial number: n/a
batch/lot number: 1100319281
model/catalog description: reservoir 65 ml pc/iz
unique identifier (udi) #: (b)(4).
|
| |
|