It was reported that during a linx removal procedure, the sales representative entered the operating room and observed the surgeon dissecting the linx device from the stomach.Following the procedure, the sales rep.Inquired whether the patient's condition would be revised to perform a gastric bypass; however, the surgeon indicated that the patient had already undergone a gastric bypass procedure.It was reported that the patient had experienced severe dysphagia associated with the linx implant, which also resulted in emotional distress.Additionally, the patient reportedly had a history of severe dysphagia prior to the initial linx implantation, which had been performed several years earlier.The device was removed during the procedure.
|
|
(b)(4).Date sent: 8/11/2026.D4: udi: as the lot number for the device involved in the event was not provided, the full udi is currently not available.D4: udi: the expiration date is currently not available.Therefore, the full udi is currently not available.An analysis of the product could not be performed since a physical sample was not received for evaluation.As part of our company quality system process, all devices are manufactured, inspected, and distributed to approved specifications.However, if the product is received at a later date, the investigation will be updated as applicable.No lot or batch number was provided therefore a device history could not be done.Additional information was requested, and the following was obtained: prior to linx placement, did the patient have an egd, ph, and manometry studies done? if yes, could you please share the results? on what date did the implant take place?
on what date did the explant take place? what is the lot number of the linx device? when using the linx sizing device what technique was used to determine the size? did the patient have an autoimmune disease? is the patient currently taking steroids / immunization drugs? did the patient have any pre-existing dysphagia or other conditions (other than gerd)? how severe was the dysphagia/odynophagia before intervention? were there any intra-operative complications during implant? was there any hiatal or crural repair done at the same time as the implant? were there any other contributing factors that led to the removal of the device other than the reported dysphagia? besides the reported dysphagia, what was the reason for removal of the linx device? what was the reason for removal of the linx device? was the device found in the correct position/geometry at the time of removal? have the symptoms resolved since the device was explanted? i¿m just not going to have many of the details you seek.Date of implant unknown.(b)(6) 2026-explant performed.It was stated by the surgeon that the original notes stated that the measurement of the implant was determined as 3 sizes higher than the sizer pop-off.According to the surgeon, patient presented with unresolved dysphagia and gerd prior to the explant performed.
|