Dentsply Implants Manufacturing GmbH PrimeTaper EV Ø3.0 x 9mm; Implant, Endosseous, Root-Form Back to Search Results
Catalog Number 68011086
Medical Device Problem Code Failure to Osseointegrate (1863)
Health Effect - Clinical Code Failure of Implant (1924)
Date of Event 06/28/2026
Type of Reportable Event Serious Injury
Event or Problem Description
It was reported that a patient experienced a dental implant loss.
 
Additional Manufacturer Narrative
Therefore, because a serious injury resulted, this event is reportable per 21 cfr part 803.The device was not evaluated because the issue is a known inherent risk of the device.We will continue to track and monitor the trend.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
PrimeTaper EV Ø3.0 x 9mm
Common Device Name
Implant, Endosseous, Root-Form
Manufacturer (Section D)
Dentsply Implants Manufacturing GmbH
rodenbacher chaussee 4
hanau hessen 63457
GM  63457
Manufacturer (Section G)
Dentsply Implants Manufacturing GmbH
rodenbacher chaussee 4
hanau hessen 63457
GM   63457
Manufacturer Contact
dan eagar
221 west philadelphia st.
york, PA 17401
+1(717)845-7511
MDR Report Key50220695
Report Number3013111692-2026-25591
Device Sequence Number18706029
Product Code DZE
UDI-Device Identifier07392532276590
UDI-Public07392532276590
Combination Product (Y/N)N
Initial Reporter CountryIT
PMA/510(K) Number
UNK
Number of Events Summarized1
Summary Report (Y/N)N
Device Implanted Year2026
Device Explanted Year2026
Serviced by Third Party (Y/N)N
Reporter Type Manufacturer
Report Source Foreign,Health Professional
Initial Reporter Occupation Dentist
Type of Report Initial
Report Date (Section B) 08/12/2026
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Operator of Device Health Professional
Device Catalogue Number68011086
Device Lot Number502840
Was Device Available for Evaluation? Yes
Date Returned to Manufacturer07/29/2026
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 07/28/2026
Initial Report FDA Received Date08/12/2026
Was Device Evaluated by Manufacturer? (Y/N) Device Not Returned to Manufacturer
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Concomitant Medical Products
and Therapy/Usage Dates
not provided
Outcome Attributed to Adverse Event Required Intervention;
Patient SexUnknown
-
-