Align Technology, Inc. Invisalign System - Comprehensive; ALIGNER, SEQUENTIAL Back to Search Results
Model Number 9000
Medical Device Problem Code Adverse Event Without Identified Device or Use Problem (2993)
Health Effect - Clinical Codes Tooth Fracture (2428); Tooth Loss (4831)
Date of Event 07/20/2026
Type of Reportable Event Serious Injury
Event or Problem Description
The treating doctor reported that the patient had symptoms of root fracture of tooth ur4 resulting in extraction of the tooth that will require a bridge to be placed.No additional information is available at this time.Attempts to obtain additional information about the event were unsuccessful.
 
Additional Manufacturer Narrative
The current instructions for use contains the following: "precautions - a tooth that has been previously traumatized or significantly restored may be aggravated.In rare instances, the useful life of the tooth may be reduced, the tooth may require additional dental treatment such as endodontic and/or additional restorative work, and/or the tooth may be lost." no root cause provided.Align's clinical review noted that available records included an initial panoramic radiograph demonstrating that ur4 had previously undergone endodontic treatment, appeared restored with a dental crown, and exhibited horizontal bone loss extending to approximately the middle third of the root.The patient completed two phases of orthodontic treatment consisting of 29 aligners and 16 aligners, respectively.Ur4 was included in the treatment plan and served as an attachment point for an elastic through a button during the second treatment phase.There is no conclusive evidence provided that supports or opposes whether the invisalign system caused or contributed to the reported permanent damage.Based on the available information, the patient had permanent damage, and the invisalign system was being used.Therefore, an mdr will be filed in the united states per 21 cfr 803.The exact date of the event is unknown.Despite reasonable efforts, no conclusive information was available to determine when the event occurred.The date (b3) provided corresponds to the date the event was reported to the manufacturer and does not necessarily reflect the actual date of occurrence.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
Invisalign System - Comprehensive
Common Device Name
ALIGNER, SEQUENTIAL
Manufacturer (Section D)
Align Technology, Inc.
2820 orchard parkway
san jose CA 95134
Manufacturer (Section G)
Align Technology, Inc.
2820 orchard parkway
san jose CA 95134
Manufacturer Contact
janier duarte santana
2820 orchard parkway
san jose, CA 95134
MDR Report Key50221103
Report Number2953749-2026-02240
Device Sequence Number10578437
Product Code NXC
UDI-Device Identifier00816063020189
UDI-Public(01)00816063020189(10)0224288408(13)260619(91)2380627816N
Combination Product (Y/N)N
Initial Reporter CountryJA
PMA/510(K) Number
K241412
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)N
Reporter Type Manufacturer
Report Source Foreign,Health Professional
Initial Reporter Occupation Dentist
Type of Report Initial
Report Date (Section B) 08/12/2026
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Operator of Device Lay User/Patient
Device Model Number9000
Device Lot Number224288408
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 07/20/2026
Initial Report FDA Received Date08/12/2026
Was Device Evaluated by Manufacturer? (Y/N) No
Date Device Manufactured06/19/2026
Is the Device Labeled for Single Use? (Y/N) No
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Unknown
Patient Sequence Number1
Outcome Attributed to Adverse Event Disability;
Patient Age43 YR
Patient SexFemale
-
-