• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: W. L. Gore & Associates, Inc. GORE® VIABAHN® VBX Balloon Expandable Endoprosthesis; Iliac Covered Stent, Arterial

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

W. L. Gore & Associates, Inc. GORE® VIABAHN® VBX Balloon Expandable Endoprosthesis; Iliac Covered Stent, Arterial Back to Search Results
Catalog Number BXB065902A
Medical Device Problem Code Deformation Due to Compressive Stress (2889)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 08/06/2026
Type of Reportable Event Serious Injury
Event or Problem Description
The following was reported to gore: on (b)(6) 2026, a patient underwent an endovascular procedure for abdominal aorta aneurysm treatment.Gore® excluder® thoracoabdominal branch endoprosthesis (tambe) was implanted.Gore® viabahn® vbx balloon expandable endoprosthesis (vbx devices) were implanted as branch devices in the visceral arteries.As reported, the physician stated a potential kink of the 6mm vbx device in right renal artery was noted post operatively.The patient experienced high blood pressure after the index procedure.This resolved after the patient's first bowel movement.On (b)(6) 2026, the vbx device kink was confirmed and reintervention was performed.The vbx device was relined with a 7mm x 30mm protege everflex stent.Result was resolution of the kink.The physician reportedly stated the cause of kink was external compression of the arcuate ligament.
 
Additional Manufacturer Narrative
Cbas® heparin surface incorporates carmeda heparin manufactured from heparin sodium api, which is covalently bound to the device surface and is essentially non-eluting.H6 - code c19: review of device manufacturing record history confirmed device met pre-release specifications.H6 - code b01: the device remains implanted; therefore, it was not available for analysis.No images enabling direct assessment of product performance were available for evaluation.W.L.Gore & associates, inc.(gore) is submitting this report to comply with 21 c.F.R.Part 803, the medical device reporting regulation.This report is based upon information obtained by gore, which the company may not have been able to fully investigate or verify prior to the date the report was required by the fda.Blank fields present on this report include required fields and fields determined to be not applicable.Blank required fields indicate that the information was not provided, was deemed unavailable or was not applicable.This report does not constitute an admission or a conclusion by fda, gore, or its associates that the device, gore or its associates caused or contributed to the event described in the report.In particular, this report does not constitute a legal admission by anyone that the product described in this report has any defects or has malfunctioned, as defined from a legal standpoint.These words are included in the report and are fixed items for selection created by the fda, to categorize the type of event solely for the purpose of reporting pursuant to part 803.This statement should be included with any information or report disclosed to the public under the freedom of information act.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
GORE® VIABAHN® VBX Balloon Expandable Endoprosthesis
Common Device Name
Iliac Covered Stent, Arterial
Manufacturer (Section D)
W. L. Gore & Associates, Inc.
1505 n. fourth street
flagstaff AZ 86004
Manufacturer (Section G)
Medical Echo Ridge B/P
3250 w. kiltie lane
flagstaff AZ 86005
Manufacturer Contact
genevieve
1505 n. fourth street
flagstaff, AZ 86004
+1(928)526-3030
MDR Report Key50224083
Report Number2017233-2026-07902
Device Sequence Number21424139
Product Code PRL
UDI-Device Identifier00733132658466
UDI-Public(01)00733132658466(17)281027
Combination Product (Y/N)Y
Initial Reporter StateCA
Initial Reporter CountryUS
PMA/510(K) Number
P160021
Number of Events Summarized1
Summary Report (Y/N)N
Device Implanted Year2026
Serviced by Third Party (Y/N)N
Reporter Type Manufacturer
Report Source Health Professional,User Facility,Company Representative
Initial Reporter Occupation Physician
Type of Report Initial
Report Date (Section B) 08/12/2026
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Operator of Device Health Professional
Device Catalogue NumberBXB065902A
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 08/06/2026
Initial Report FDA Received Date08/12/2026
Was Device Evaluated by Manufacturer? (Y/N) No
Date Device Manufactured10/29/2025
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Outcome Attributed to Adverse Event Required Intervention;
Patient Age60 YR
Patient SexMale
-
-