Abiomed, Inc. - 1220648 Kit, 14Fr Introducer, 13cm&25cm, Sterile; Introducer, Catheter (Introducer)
|
Back to Search Results |
|
| Catalog Number |
0052-3046 |
| Medical Device Problem Code |
Patient Device Interaction Problem (4001)
|
| Health Effect - Clinical Code |
Hemorrhage/Blood Loss/Bleeding (1888)
|
| Date of Event |
07/27/2026
|
|
Type of Reportable Event
|
Death
|
|
Event or Problem Description
|
|
An impella cp device was inserted via the femoral artery in a 56 year-old male patient with an indication not reported.The access side was reported as unknown.The patient¿s clinical state prior to initiation of support was society for cardiovascular angiography and interventions (scai) shock stage e.The patient's medical history was not reported.During support, a hematoma developed at the impella access site around the repositioning sheath.Hemostasis was achieved by manual pressure.It was reported that the repositioning sheath was properly placed with angle matching.No further intervention or treatments were reported.The anticoagulation status prior and during support was also not reported.It was noted that the patient did require the hemodynamic support with the use of 3 vasopressor and inotropes during support.The following morning the patient subsequently expired on support.While on support, the impella cp device operated at performance level 8 with expected flows of 3.2 liters/minute.The purge solution consisted of dextrose 5% in water with 25 milliequivalents per liter sodium bicarbonate.The reported hematoma and access site bleeding cannot be dissociated from the impella, as the bleeding occurred around the access site.The death also cannot be dissociated from the impella due to the reported bleeding.However, the death most likely attributed to the patient's underlying critical condition, as they presented in scai stage e shock and required the support with 3 vasopressors and inotropes.
|
| |
|
Additional Manufacturer Narrative
|
|
This report is being submitted pursuant to the provisions of 21 cfr, part 803.This report may be based on information which has not been investigated or verified prior to the required reporting date.This report does not reflect a conclusion by abiomed inc, or its employees that the report constitutes an admission that the product, abiomed inc, or its employees caused or contributed to the potential event described in this report.If information is obtained that was not available for the initial report, a follow-up report will be filed as appropriate.
|
| |
|
Search Alerts/Recalls
|
|
|