| Model Number |
CDS0801-XT |
| Medical Device Problem Code |
Adverse Event Without Identified Device or Use Problem (2993)
|
| Health Effect - Clinical Codes |
Shock (2072); Unspecified Tissue Injury (4559)
|
| Date of Event |
07/27/2026
|
|
Type of Reportable Event
|
Death
|
|
Event or Problem Description
|
|
It was reported that on (b)(6) 2026, a patient presented with grade 3+ mixed mitral regurgitation (mr), prolapsed posterior leaflet, coaptation gap of nearly 10 mm and enlarged atrium for a mitraclip procedure.The initial screening mr grade 3+ but worsened to 4+ at the start of the procedure.The cause was unknown.During the procedure, the mitraclip xtw was implanted.The decision was made to implant a second mitraclip xt.Grasping was attempted and after a few grasping attempts, it was observed that there was a torn anterior leaflet.The second mitraclip xt was removed from the patient.The first clip remained stable.The final mr was grade 4+.The following day, the patient went into shock and passed away.The patient's family declined additional intervention and medical therapy.The physician believed worsening heart failure and significantly severe mr prior to the procedure, in addition to the torn tissue likely contributed to the death.
|
| |
|
Event or Problem Description
|
|
It was reported that on (b)(6) 2026, a patient presented with grade 3+ mixed mitral regurgitation (mr), prolapsed posterior leaflet, coaptation gap of nearly 10 mm and enlarged atrium for a mitraclip procedure.The initial screening mr grade 3+ but worsened to 4+ at the start of the procedure.The cause was unknown.During the procedure, the mitraclip xtw was implanted.The decision was made to implant a second mitraclip xt.Grasping was attempted and after a few grasping attempts, it was observed that there was a torn anterior leaflet.The second mitraclip xt was removed from the patient.The first clip remained stable.The final mr was grade 4+.The following day, the patient went into shock and passed away.The patient's family declined additional intervention and medical therapy.The physician believed worsening heart failure and significantly severe mr prior to the procedure, in addition to the torn tissue likely contributed to the death.
|
| |
|
Additional Manufacturer Narrative
|
|
The device will not be returned for evaluation, the device was reportedly discarded.Investigation is not yet complete.A follow-up report will be submitted with all additional relevant information.
|
| |
|
Additional Manufacturer Narrative
|
|
The device was not returned for analysis.A review of the lot history record revealed no manufacturing nonconformities issued to the reported lot that would have contributed to this event.The provided event details was reviewed by an abbott director of medical affairs.The investigation was unable to determine the cause for the reported unspecified issue injury, death, and shock.Unspecified issue injury, death, and shock are listed in the instructions for use as known possible complications associated with the mitraclip procedures.There is no indication of a product issue with respect to manufacture, design, or labeling.
|
| |
|