Model Number 0684-00-0576-01
Medical Device Problem Codes Device Sensing Problem (2917); Material Deformation (2976); Material Split, Cut or Torn (4008)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 08/05/2026
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
Updated fields: b4, g3, g6, h2, h6(medical device problem code, type of investigation, investigation findings, component codes, investigation conclusions), h11.Correction field: d1, d4, d10, h3.The iab was returned with the membrane completely unfolded and blood on the exterior of the catheter and between the catheter and the sheath.The returned sheath was over the catheter and partially covering the rear portion of the balloon.The sensor cable, pressure and extracorporeal tubing were returned cut in two parts.A kink was observed on the catheter tubing approximately 39.6cm from iab tip.Upon receipt, the sensor cable was found cut into two separate parts.As a result, we were unable to perform the required sensor test.We were unable to conclusively determine if there was a problem with the ability to monitor the pressure waveform due to the returned condition of the iab as we were unable to fully evaluate the iab.The reported event cannot be confirmed by the evaluation.
 
Event or Problem Description
N/a.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
SENSATION PLUS 8Fr. 50cc IAB & Accessories (w/Pressure Tubes, No Stylet)
Common Device Name
System, Balloon, Intra-Aortic And Control
Manufacturer (Section D)
Datascope Corp.
15 law drive
fairfield NJ 07004
Manufacturer (Section G)
Datascope Corp.
15 law drive
fairfield NJ 07004
Manufacturer Contact
ewelina chorlowska
15 law drive
fairfield, NJ 07004
MDR Report Key50493646
Report Number2248146-2026-0001464
Device Sequence Number10224291
Product Code DSP
UDI-Device Identifier10607567109633
UDI-Public(01)10607567109633(10)3000525520(17)290202(11)260202
Combination Product (Y/N)N
Initial Reporter StateCA
Initial Reporter CountryUS
PMA/510(K) Number
K122327
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)N
Reporter Type Manufacturer
Report Source Health Professional
Initial Reporter Occupation Nurse
Type of Report Initial,Followup
Report Date (Section B) 09/16/2026
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Model Number0684-00-0576-01
Device Catalogue Number0684-00-0576-01
Device Lot Number3000525520
Was Device Available for Evaluation? Yes
Is the Reporter a Health Professional? No
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 08/05/2026
Supplement Date Received by Manufacturer09/15/2026
Initial Report FDA Received Date08/28/2026
Supplement Report FDA Received Date09/16/2026
Was Device Evaluated by Manufacturer? (Y/N) Yes
Date Device Manufactured02/02/2026
Is the Device Labeled for Single Use? (Y/N) Yes
Usage of Device Initial
Patient Sequence Number1
Concomitant Medical Products
and Therapy/Usage Dates
Intra-Aortic Balloon Pump (IABP)
Patient Age70 YR
Patient SexMale
Patient Weight215 LB
-
-