The physical device was not returned.Cloud data for the period of (b)(6) 2026-(b)(6) 2026 was downloaded and reviewed.Cloud data indicated that the system was operating primarily in automated mode.While in automated mode, the algorithm adapted microbolus delivery as intended in response to fluctuations in estimated glucose values (egvs).As egvs increased, the system correctly increased microbolus delivery.As egvs began to plateau and decrease, the algorithm suspended delivery until egvs began to increase once again.Multiple user-initiated boluses were programmed and delivered successfully.The pulses delivered count aligns with the programmed bolus values and algorithm microbolus delivery, confirming that the active pods were delivered the correct amount of insulin per user inputs.Cloud data indicated that no pods were activate between 20:50 on (b)(6) 2026 and 08:15 on (b)(6) 2026.After the new pod was activated at (b)(6) 2026, the algorithm was confirmed to have continued to function as intended after the gap in pod activation.Exit closed loop alerts were generated at multiple times during the period of cloud data review.Alerts were generated at 12:56 on(b)(6) 2026, 00:42 on (b)(6) 2026, and 17:52 on (b)(6) 2026, each after delivering insulin at the maximum rate for an extended period of time.After these alerts were acknowledged, the system correctly transitioned to manual mode before eventually transitioning back to automated mode.Missing egv alerts were prompted at 18:27 on (b)(6) 2026 and 17:42 on (b)(6) 2026 after consecutive cycles of missing egvs.The system correctly transitioned into limited mode until connection between the pod and sensor was restored.While the system was operating in manual mode, it delivered insulin at the user's set basal rate regardless of egvs received.The last egv reading occurred at approximately 17:28 on (b)(6) 2026 with an egv of 150 mg/dl shortly prior to the last recorded pod deactivation.No evidence was found that would indicate that the system was failing to operate and deliver insulin as intended.Lot release records were reviewed and the product lot met all acceptance criteria.Locked down smartphone: data not available
omnipod software app version: 3.1.6
operating system: n5004l-am-q-mv01602-06-01.06
hardware: n5004l
cgm sensor type: data not available
please note, the device identifiers are captured as reported by the complainant and may not align with the device configuration reported in this section as this data is pulled from our cloud based on the reported date of event.
|