| Model Number |
CDS0801-NT |
| Medical Device Problem Code |
Adverse Event Without Identified Device or Use Problem (2993)
|
| Health Effect - Clinical Codes |
Heart Failure/Congestive Heart Failure (4446); Mitral Valve Insufficiency/ Regurgitation (4451)
|
| Date of Event |
08/04/2026
|
|
Type of Reportable Event
|
Death
|
|
Event or Problem Description
|
|
It was reported that on (b)(6) 2026, a patient presented with grade 4 functional mitral regurgitation (mr), thin friable tissue for a mitraclip procedure.During the procedure, two mitraclip xt were implanted.During implantation of a third mitraclip xt, multiple grasps were made on the friable tissue.A leaflet tear was then observed.The third clip was removed from the patient and replaced with a mitraclip nt.The third clip was implanted.The final mr remained at grade 4.On (b)(6) 2026 the patient presented with heart failure with a v wave of 70mmhg.A balloon pump was inserted but did not resolve symptoms.The patient passed away.The clips remained stable at the time of death.The physician believed the tissue injury was due to the mitraclip and overall tissue integrity.
|
| |
|
Event or Problem Description
|
|
It was reported that on (b)(6) 2026, a patient presented with grade 4 functional mitral regurgitation (mr), thin friable tissue for a mitraclip procedure.During the procedure, two mitraclip xt were implanted.During implantation of a third mitraclip xt, multiple grasps were made on the friable tissue.A leaflet tear was then observed.The third clip was removed from the patient and replaced with a mitraclip nt.The third clip was implanted.The final mr remained at grade 4.On (b)(6) 2026 the patient presented with heart failure with a v wave of 70mmhg.A balloon pump was inserted but did not resolve symptoms.The patient passed away.The clips remained stable at the time of death.The physician believed the tissue injury was due to the mitraclip and overall tissue integrity.
|
| |
|
Additional Manufacturer Narrative
|
|
Manufacturer's investigation is still pending at this time.Results and conclusions will be provided in the final report.
|
| |
|
Additional Manufacturer Narrative
|
|
The device was not returned for analysis.A review of the lot history record revealed no manufacturing nonconformities issued to the reported lot that would have contributed to this event.Based on available information, the cause of the reported death, mitral valve regurgitation, and heart failure were unable to be determined.The reported patient effects of death, mitral regurgitation, and heart failure, as listed in the mitraclip system instructions for use, are known possible complications associated with mitraclip procedures.The reported unexpected medical intervention was results of case-specific circumstances.There is no indication of a product quality issue with respect to manufacture, design, or labeling.
|
| |
|