• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: W. L. Gore & Associates, Inc. GORE® TAG® Conformable Thoracic Stent Graft with ACTIVE CONTROL System; System, Endovascular Graft, Aortic Aneurysm Treatment

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

W. L. Gore & Associates, Inc. GORE® TAG® Conformable Thoracic Stent Graft with ACTIVE CONTROL System; System, Endovascular Graft, Aortic Aneurysm Treatment Back to Search Results
Catalog Number TGMR313110
Medical Device Problem Code Adverse Event Without Identified Device or Use Problem (2993)
Health Effect - Clinical Code Stroke/CVA (1770)
Date of Event 06/17/2026
Type of Reportable Event Serious Injury
Event or Problem Description
The following was reported from the imedidata study database: on (b)(6) 2026, a patient was treated for a thoracoabdominal aneurysm following open repair of a dissection using a gore® tag® conformable thoracic stent graft with active control system.On the same day, after the procedure, a stroke was noted.Imaging demonstrated a clinical infarct.No treatment was given, and the patient recovered (b)(6) 2026.
 
Additional Manufacturer Narrative
H.6.Investigation findings code c21: conclusions pending results of product history review.W.L.Gore & associates, inc.(gore) is submitting this report to comply with 21 c.F.R.Part 803, the medical device reporting regulation.This report is based upon information obtained by gore, which the company may not have been able to fully investigate or verify prior to the date the report was required by the fda.Blank fields present on this report include required fields and fields determined to be not applicable.Blank required fields indicate that the information was not provided, was deemed unavailable or was not applicable.This report does not constitute an admission or a conclusion by fda, gore, or its associates that the device, gore or its associates caused or contributed to the event described in the report.In particular, this report does not constitute a legal admission by anyone that the product described in this report has any defects or has malfunctioned, as defined from a legal standpoint.These words are included in the report and are fixed items for selection created by the fda, to categorize the type of event solely for the purpose of reporting pursuant to part 803.This statement should be included with any information or report disclosed to the public under the freedom of information act.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
GORE® TAG® Conformable Thoracic Stent Graft with ACTIVE CONTROL System
Common Device Name
System, Endovascular Graft, Aortic Aneurysm Treatment
Manufacturer (Section D)
W. L. Gore & Associates, Inc.
1505 n. fourth street
flagstaff AZ 86004
Manufacturer (Section G)
Medical Woody Springs B/P
3450 w. kiltie lane
flagstaff AZ 86005
Manufacturer Contact
bryce wargin
1505 n. fourth street
flagstaff, AZ 86004
+1(928)526-3030
MDR Report Key50501088
Report Number2017233-2026-07958
Device Sequence Number10087292
Product Code MIH
UDI-Device Identifier00733132646777
UDI-Public(01)00733132646777(17)270714
Combination Product (Y/N)N
Initial Reporter CountryUS
PMA/510(K) Number
P040043
Number of Events Summarized1
Summary Report (Y/N)N
Device Implanted Year2026
Serviced by Third Party (Y/N)N
Reporter Type Manufacturer
Report Source Study
Initial Reporter Occupation Physician
Type of Report Initial
Report Date (Section B) 08/28/2026
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Device Catalogue NumberTGMR313110
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 08/03/2026
Initial Report FDA Received Date08/28/2026
Date Device Manufactured07/15/2024
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Concomitant Medical Products
and Therapy/Usage Dates
Hypercholesterolemia medication (unspecified), Hyp.
Outcome Attributed to Adverse Event Other;
Patient Age71 YR
Patient SexMale
Patient Weight206 LB
Patient RaceWhite
-
-