| Catalog Number |
GST45B |
| Medical Device Problem Code |
Failure to Fire (2610)
|
| Health Effect - Clinical Code |
No Clinical Signs, Symptoms or Conditions (4582)
|
| Date of Event |
07/27/2026
|
|
Type of Reportable Event
|
Malfunction
|
|
Event or Problem Description
|
|
It was reported that during an unknown procedure the gst reload couldn't fire properly.Was surgery delayed due to the reported event? unknown,
was procedure successfully completed? unknown,
were fragments generated? unknown,
if yes, were they removed easily without additional intervention? unknown,
patient status/ outcome / consequences: no,
patient consequence description/was there a clinical outcome experienced by the patient (infection, inflammation, etc.)? no incidence of infection or inflammation,
was other medical intervention (e.G.X-rays, additional procedures, prescriptions, otc, revision) required: unknown.
|
| |
|
Additional Manufacturer Narrative
|
|
(b)(4).Date sent 8/31/2026.D4 batch # 812d43.Investigation summary.The product was returned for evaluation.Visual inspection was conducted on the returned reload.Visual analysis of the returned sample determined that one gst45b reload was received fully fired.Upon further inspection, the reload was found to have damaged on the knife channel, it is possible that the knife may push the staple line and tissue forward shaving the reload knife channel.No functional test could be performed due to the condition of the reload.To mitigate the potential for staples getting into the reload and interfering with the knife path during device firing, prior to reloading the device, rinse the anvil and reload jaw in sterile solution and then wipe the anvil and reload jaw to clean any formed but unused staples from the device.Additionally, proper care should be taken when placing the device on the tissue to be stapled, to ensure that no hard obstruction such as a clip is included with the tissue inside the jaws.Please reference the instruction for use for more information.As part of ethicon endo surgery¿s quality process, all devices are manufactured, inspected, and released to approved specifications.A manufacturing record evaluation was performed for the finished device batch number 812d43, and no non-conformances were identified.Additional information was requested, and the following was obtained:
please explain in detail what was the issue with the device.Was the firing sequence started but not completed? yes
if yes: did the device deliver any staples? na.If yes, were the staples formed properly? na.If yes, was the staple line complete? na.Did the device cut? no.If yes, was the cut line complete? na.If yes, was there any issue with the cut line such as jagged, dull knife, irregular, etc? na.Was there any difficulty opening the device? no.If yes, how was the device removed from the patient? na.If yes, did the jaws eventually open? na.
|
| |
|