Model Number 0684-00-0607
Medical Device Problem Codes Signal Artifact/Noise (1036); Leak/Splash (1354)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 08/11/2026
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
Please revert the a1 (patient id) a3 d8 to blank updated fields- b1, b4, d9, d10, g3, g4, g6, g7, h2, h3, h6 (type of investigation, investigation findings, component codes, investigation conclusions), h11 the iab was returned with the membrane completely unfolded and blood on the interior and exterior of the catheter.The extender and pressure tubing were also returned.A sensor output test was performed and the sensor was found to be within specification.An underwater leak test of the balloon, catheter, y fitting, extracorporeal, extender and pressure tubing was performed and a leak was detected on the membrane approximately 1.5cm from the rear seal measuring 0.025cm in length.The reported difficult unable to monitor waveform pressure cannot be confirmed by the evaluation.The reported leak was most likely triggered by a leak which was found on the membrane.Under magnification, a whitish patch was observed around the leak.This whitish patch is the typical appearance of an abrasion mark which is caused by calcified plaque in the aorta.
 
Event or Problem Description
N/a.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
TRANS-RAY PLUS 7.5Fr 35cc IAB WITH ACCESSORIES
Common Device Name
System, Balloon, Intra-Aortic And Control
Manufacturer (Section D)
Datascope Corp.
15 law drive
fairfield NJ 07004
Manufacturer (Section G)
Datascope Corp.
15 law drive
fairfield NJ 07004
Manufacturer Contact
ewelina chorlowska
15 law drive
fairfield, NJ 07004
MDR Report Key50539970
Report Number2248146-2026-0001489
Device Sequence Number9432403
Product Code DSP
UDI-Device Identifier10607567111711
UDI-Public(01)10607567111711(17)280115(10)3000445579(11)250115
Combination Product (Y/N)N
Initial Reporter CountryJA
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)N
Reporter Type Manufacturer
Report Source Foreign,Health Professional,User Facility,Company Representative
Initial Reporter Occupation Physician
Type of Report Initial
Report Date (Section B) 09/01/2026
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Model Number0684-00-0607
Device Catalogue Number0684-00-0607
Device Lot Number3000445579
Was Device Available for Evaluation? Yes
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 08/12/2026
Initial Report FDA Received Date09/01/2026
Was Device Evaluated by Manufacturer? (Y/N) No
Date Device Manufactured01/15/2025
Is the Device Labeled for Single Use? (Y/N) Yes
Usage of Device Initial
Patient Sequence Number1
Concomitant Medical Products
and Therapy/Usage Dates
Cardiosave.
Patient SexUnknown
-
-