• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: BOSTON SCIENTIFIC CORPORATION CRE PRO; Catheter, Biliary, Diagnostic

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

BOSTON SCIENTIFIC CORPORATION CRE PRO; Catheter, Biliary, Diagnostic Back to Search Results
Model Number M00558710
Medical Device Problem Codes Burst Container or Vessel (1074); Difficult to Advance (2920)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 08/04/2026
Type of Reportable Event Malfunction
Event or Problem Description
It was reported to boston scientific corporation (bsc) that a cre pro wireguided dase dilatation balloon was attempted to be used in the esophagus during an esophageal stricture procedure performed on (b)(6) 2026.During the procedure, resistance was encountered when threading the balloon through the working channel of the scope.Upon inflation with the syringe assembly, the balloon burst inside the patients esophagus.The customer stated that no pieces of the balloon detached inside the patient.The procedure was completed with another cre pro wireguided dase dilatation balloon of a different lot number and a non-bsc inflation device.There were no patient complications reported as a result of this event.The patients condition at the conclusion of the procedure was reported to be stable.Additional information received 03 sep 2026.Patient was having an esophagogastroduodenoscopy (egd) dilation and a cre pro wireguided dilator measurements 18-20mm was used.Instrument appeared intact, all checks completed.The balloon was inflated as normal, but the balloon burst while in the patient's esophagus at the max pressure.No injury to the patient, however, a new instrument had to be used during the procedure.
 
Additional Manufacturer Narrative
Block h6: imdrf device code a0402 captures the reportable event of balloon burst.Block h11: investigation results: the device was not returned for analysis and was reported to be disposed; therefore, a technical analysis could not be performed.With all available information, boston scientific concludes the reported event of balloon burst could not be confirmed.Based on a thorough review of the reported complaint, boston scientific has assigned an investigation conclusion code of cause not established.The device history record review confirmed that the device met all material, assembly, and performance specifications prior to distribution.A similar complaint review was completed.There were no emerging trends identified that warrant further action.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
CRE PRO
Common Device Name
Catheter, Biliary, Diagnostic
Manufacturer (Section D)
BOSTON SCIENTIFIC CORPORATION
300 boston scientific way
marlborough MA 01752
Manufacturer (Section G)
Boston Scientific Cork Limited
cork business technology park
model farm road
cork T12 Y K88
EI   T12 YK88
Manufacturer Contact
christina lam
300 boston scientific way
marlborough, MA 01752
+1(914)571-6918
MDR Report Key50550084
Report Number3005099803-2026-03493
Device Sequence Number10265899
Product Code FGE
UDI-Device Identifier08714729797593
UDI-Public(01)08714729797593(17)281113(10)37959117
Combination Product (Y/N)N
Initial Reporter CountryCA
PMA/510(K) Number
K112994
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source Other,Foreign,Health Professional,Company Representative
Initial Reporter Occupation Non-Healthcare Professional
Type of Report Initial,Followup
Report Date (Section B) 09/20/2026
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Model NumberM00558710
Device Catalogue NumberM00558710
Device Lot Number0037959117
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? No
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 08/04/2026
Supplement Date Received by Manufacturer08/26/2026
Initial Report FDA Received Date09/01/2026
Supplement Report FDA Received Date09/21/2026
Was Device Evaluated by Manufacturer? (Y/N) No
Date Device Manufactured11/14/2025
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Patient SexUnknown
-
-