BOSTON SCIENTIFIC CORPORATION FARAWAVE; Percutaneous Cardiac Ablation Catheter For Treatment Of Atrial Fibrillation With Irreversible Electroporation Back to Search Results
Lot Number 0039159150
Medical Device Problem Codes Nonstandard Device (1420); Physical Resistance/Sticking (4012)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 08/05/2026
Type of Reportable Event Malfunction
Event or Problem Description
During an atrial fibrillation ablation, a farawave ablation catheter was selected for use.During preparation, it was noted that the wire had a slight resistance when pulling back into the catheter.After an additional inspection, a small fragmentation was noticed at the distal tip of the catheter.The catheter was replaced and procedure was completed with no patient complications.
 
Event or Problem Description
During an atrial fibrillation ablation, a farawave ablation catheter was selected for use.During preparation, it was noted that the wire had a slight resistance when pulling back into the catheter.After an additional inspection, a small fragmentation was noticed at the distal tip of the catheter.The catheter was replaced and procedure was completed with no patient complications.
 
Additional Manufacturer Narrative
D2a: common device name: percutaneous cardiac ablation catheter for treatment of atrial fibrillation with irreversible electroporation; reported here as the common device name exceeded the character limit for designated field.
 
Additional Manufacturer Narrative
D2a: common device name: percutaneous cardiac ablation catheter for treatment of atrial fibrillation with irreversible electroporation; reported here as the common device name exceeded the character limit for designated field.Device technical analysis: during product analysis the device passed all tests performed, showing no evidence of the reported failure.Additionally, no damage or defects were observed during the analysis.Device history record review: it was confirmed this device met specification prior to distribution and there were no manufacturing deviations which could have contributed to the reported event.Labeling review: based on the information provided, there is no evidence that the device was used in a manner inconsistent with the labelled indications/instructions for use (ifu).Risk review: a risk review performed for the fawave device confirmed that the event of damage and difficult to load wire are known events defined in the products risk management documentation.This event type has been accounted for during product risk analysis to support acceptable risk benefit for the product.Investigation conclusion: boston scientific has assigned an investigation conclusion code of no problem detected for the reported allegations as the allegations were unable to be confirmed, and no issues were observed during the analysis.A guidewire was successfully inserted through the catheter.Deployment was tested multiple times, and the device was deployed to basket and flower position with no unusual resistance noted.The device passed all tests performed, showing no evidence of the reported failure.Additionally, no damage or defects were observed during the analysis.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
FARAWAVE
Common Device Name
Percutaneous Cardiac Ablation Catheter For Treatment Of Atrial Fibrillation With Irreversible Electroporation
Manufacturer (Section D)
BOSTON SCIENTIFIC CORPORATION
300 boston scientific way
marlborough MA 01752
Manufacturer (Section G)
Boston Scientific Corporation
302 parkway, global park
la aurora - heredia
CS  
Manufacturer Contact
mary crawford
4100 hamline avenue north
dc a330
saint paul, MN 55112
+1(651)440-0979
MDR Report Key50565498
Report Number2124215-2026-46850
Device Sequence Number21355218
Product Code QZI
UDI-Device Identifier00191506043216
Combination Product (Y/N)N
Initial Reporter StateNE
Initial Reporter CountryUS
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source Health Professional,User Facility,Company Representative
Initial Reporter Occupation Physician
Type of Report Initial,Followup
Report Date (Section B) 09/28/2026
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Lot Number0039159150
Was Device Available for Evaluation? Yes
Date Returned to Manufacturer08/11/2026
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 08/05/2026
Supplement Date Received by Manufacturer09/16/2026
Initial Report FDA Received Date09/02/2026
Supplement Report FDA Received Date09/28/2026
Was Device Evaluated by Manufacturer? (Y/N) Yes
Date Device Manufactured04/23/2026
Is the Device Labeled for Single Use? (Y/N) Yes
Usage of Device Initial
Patient Sequence Number1
Patient SexUnknown
-
-