• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: Dentsply Implants Manufacturing GmbH OsseoSpeed TX 5.0S - 9 mm; implant, endosseous, root-form

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

Dentsply Implants Manufacturing GmbH OsseoSpeed TX 5.0S - 9 mm; implant, endosseous, root-form Back to Search Results
Catalog Number 24971
Medical Device Problem Code Loss of Osseointegration (2408)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 04/13/2026
Type of Reportable Event Serious Injury
Event or Problem Description
It was reported that a patient experienced a dental implant loss.There was no reported injury.
 
Additional Manufacturer Narrative
Since this event resulted in a serious injury, it is reportable per 21 cfr part 803.The device was not evaluated because the issue is a known inherent risk of the device.We will continue to track and monitor the trend.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
OsseoSpeed TX 5.0S - 9 mm
Common Device Name
implant, endosseous, root-form
Manufacturer (Section D)
Dentsply Implants Manufacturing GmbH
rodenbacher chaussee 4
63457 hanau
hessen
GM 
Manufacturer (Section G)
Dentsply IH AB
aminogatan 1
s-431 21 molndal vastra gotala
Manufacturer Contact
dan eager
221 w. philadelphia st.
suite 60w
york, PA 17401
1(717)845-7511
MDR Report Key50591815
Report Number3013111692-2026-40008
Device Sequence Number10067452
Product Code DZE
UDI-Device Identifier07392532108136
UDI-Public07392532108136
Combination Product (Y/N)N
Initial Reporter CountryCH
PMA/510(K) Number
K053384
Number of Events Summarized1
Summary Report (Y/N)N
Device Implanted Year2025
Device Explanted Year2026
Serviced by Third Party (Y/N)N
Reporter Type Manufacturer
Report Source Foreign,Health Professional,Distributor
Initial Reporter Occupation Dentist
Type of Report Initial
Report Date (Section B) 09/03/2026
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Operator of Device Health Professional
Device Catalogue Number24971
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer Not provided
Initial Report FDA Received Date09/03/2026
Was Device Evaluated by Manufacturer? (Y/N) No
Is the Device Labeled for Single Use? (Y/N) No
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Unknown
Patient Sequence Number1
Outcome Attributed to Adverse Event Other; Required Intervention;
Patient SexUnknown
-
-