MAUDE Adverse Event Report: INTUITIVE SURGICAL, INC da Vinci Energy; SynchroSeal

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

INTUITIVE SURGICAL, INC da Vinci Energy; SynchroSeal Back to Search Results
Model Number 480440-07
Medical Device Problem Code Failure to Seal (4070)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 08/08/2026
Type of Reportable Event Malfunction
Event or Problem Description
Refer to h11 for follow-up information.
 
Additional Manufacturer Narrative
Intuitive surgical, inc.(isi) followed up with the initial reporter and obtained the following additional information: during a follow-up case on 03-sep-2026, clinical sales manager observed that the surgeon was applying the coag function before using synchroseal instrument synch mode on thin fibro-fatty tissue.When coag was used first, the system frequently displayed an ¿incomplete seal cycle¿ message.After being advised that synch mode already performs both sealing and cutting and does not require prior coag application, the surgeon used synch alone and the frequency of incomplete seal cycle messages decreased significantly.The reported issue was that the synchroseal instrument was not achieving a seal despite energy appearing to be present.No delayed sealing, partial sealing, arcing, bleeding, tissue cutting, metal contact, liquid contamination, or bio-debris contamination were reported.The instrument did not successfully seal during the procedure, and an ¿incomplete seal cycle¿ error was observed with audible tones indicating that the seal cycle had not completed.The tissue was reported to be very thin and under tension, and photos from the follow-up case were provided for review.Isi did receive a da vinci product to perform failure analysis.The synchroseal instrument was analyzed, and the complaint was not confirmed by failure analysis.Visual inspection displayed no signs of physical damage.No thermal damage to the cut electrode and no excessive bio debris.Review of the master supervisory controller (msc) showed one e100 recoverable error; however, it was not a failure.A high impedance error was triggered when the user attempted to seal or transect too much tissue between the jaws.Review of the energy logs showed no errors.The energy logs showed 27 high initial starting impedance, which is not considered a failure, as it means a high impedance error is triggered when the user attempts to seal or transect too much tissue between the jaws.No cut electrode shorted errors were shown on the energy logs.The instrument was placed and driven on an in-house system.The instrument passed the recognition and engagement tests and passed the energy recognition on 3 out of 3 attempts.The instrument sealed and transected successfully in 3 of 3 attempts.The instrument moved intuitively with full range of motion in all directions.No product issue was identified.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
da Vinci Energy
Common Device Name
SynchroSeal
Manufacturer (Section D)
INTUITIVE SURGICAL, INC
3410 central expressway
santa clara CA 95051
Manufacturer (Section G)
INTUITIVE SURGICAL, INC
3410 central expressway
santa clara CA 95051
Manufacturer Contact
izabel nielson
3410 central expressway
santa clara, CA 95051
+1(408)523-2100
MDR Report Key50593223
Report Number2955842-2026-37550
Device Sequence Number18499960
Product Code NAY
UDI-Device Identifier10886874117306
UDI-Public(01)10886874117306(17)280131(10)K11260122
Combination Product (Y/N)N
Initial Reporter CountryAS
PMA/510(K) Number
K191280
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source Other,Foreign,Health Professional
Initial Reporter Occupation Other Health Care Professional
Remedial Action Other
Type of Report Initial,Followup
Report Date (Section B) 09/29/2026
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Model Number480440-07
Device Catalogue Number480440
Device Lot NumberK11260122 0057
Was Device Available for Evaluation? Yes
Date Returned to Manufacturer09/23/2026
Is the Reporter a Health Professional? No
Initial Date Received by Manufacturer Not provided
Supplement Date Received by Manufacturer09/03/2026
Initial Report FDA Received Date09/03/2026
Supplement Report FDA Received Date09/29/2026
Was Device Evaluated by Manufacturer? (Y/N) Yes
Date Device Manufactured01/22/2026
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
If action reported to FDA under 21 USC 360i(g), list
FDA-assigned Recall Number or include a statement
N/A
Patient Sequence Number1
Patient SexUnknown
-
-