It was reported that a nstemi requiring intervention occurred.In early (b)(6) 2026, the 2.75 mm x 25 mm target lesion located at the right posterior descending vessel was pretreated with a semi-compliant and non-compliant balloon with the largest balloon being 2.5 mm x 25 mm.Maximum inflation pressure was 16 with a total of 2 balloon inflations.Pretreatment resulted in 20% stenosis and timi flow 3.The target lesion was then successfully treated with a 3.0 mm x 30 mm agent dcb balloon, maximum inflation pressure was 8 with a total of 1 balloon inflation.Prior to the target lesion treatment, the non-target lesion located at the mid left anterior descending artery was also successfully treated with a 3.5 mm x 16 mm drug eluting stent and 3.75 mm x 12 mm balloon angioplasty catheter.Patient discharged on the same day of the procedure.Shortly after the procedure in (b)(6) 2026, the patient experienced dyspnea and had a nstemi that required an in-patient hospitalization, stent placement, target vessel revascularization and medication administration (heparin).Patient discharged.It was later reported:
that shortly after the procedure in (b)(6) 2026, the patient also experienced chest pain.It was later reported:
it was reported that 70% restenosis occurred.In (b)(6) 2026, the initial procedure was completed.The patient was on a prior regimen of aspirin (>= 72 hours).At the time of the procedure heparin or other antithrombotic and a loading dose of 180 mg ticagrelor were given.The 2.75 mm x 25 mm target lesion located at the right posterior descending artery (r-pda) was pretreated with two devices resulting in 20% residual stenosis and timi flow of 3.The largest pretreatment balloon was a 2.5 mm x 25 mm semi-compliant balloon and a non-compliant balloon.The target lesion was then successfully treated with a 3.0 mm x 30 mm agent dcb achieving 0% residual stenosis and timi flow 3.The non-target lesion located at the middle left anterior descending artery was also successfully treated prior to the target lesion with a 3.5 mm x 16 mm drug eluting stent and 3.75 mm x 12 mm balloon angioplasty catheter.The patient discharged home with the continuation of aspirin and ticagrelor medications.The patient presented with shortness of breath 5 days after the initial procedure which resulted in a hospitalization.Diagnostic coronary angiography revealed 70% stenosis and a coronary artery dissection at the r-pda.Subsequently the patient was successfully implanted with a drug-eluting stent.The patient discharged from the hospital.
|