• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: BOSTON SCIENTIFIC CORPORATION FARADRIVE Steerable Sheath Clear; Catheter, Steerable

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

BOSTON SCIENTIFIC CORPORATION FARADRIVE Steerable Sheath Clear; Catheter, Steerable Back to Search Results
Lot Number CL15429
Medical Device Problem Code Air/Gas in Device (4062)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 08/19/2026
Type of Reportable Event Malfunction
Event or Problem Description
It was reported that visible air/bubbles occurred.It was reported that a faradrive sheath was selected for a pulse field ablation (pfa) to treat an atrial fibrillation (af).The sheath was prepared as normal, and no air was noted during the aspiration step.The sheath was flushed and aspirated correctly, and the dilator was inserted correctly.During insertion in the groin, the wire and dilator were removed.Then, aspiration was performed and no air was noted.The catheter was inserted into the sheath valve, and the guidewire was advanced approximately 10 cm.The physician performed two aspirations from the sheath, and both showed air in the sheath side port.Sheath was replaced and procedure was completed without patient complications.Product return is not expected as it was contaminated.It was further informed that no air was seen in the patient.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
FARADRIVE Steerable Sheath Clear
Common Device Name
Catheter, Steerable
Manufacturer (Section D)
BOSTON SCIENTIFIC CORPORATION
300 boston scientific way
marlborough MA 01752
Manufacturer (Section G)
CENTERPOINT SYSTEMS
3338 parkway blvd
west valley city UT 84119
Manufacturer Contact
mary crawford
4100 hamline avenue north
dc a330
saint paul, MN 55112
+1(651)440-0979
MDR Report Key50689658
Report Number2124215-2026-48093
Device Sequence Number21236142
Product Code DRA
UDI-Device Identifier00191506043131
Combination Product (Y/N)N
Initial Reporter CountryAS
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source Other,Foreign,Health Professional
Initial Reporter Occupation Physician
Remedial Action Notification
Type of Report Initial
Report Date (Section B) 09/09/2026
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Lot NumberCL15429
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 08/19/2026
Initial Report FDA Received Date09/09/2026
Date Device Manufactured02/26/2026
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
If action reported to FDA under 21 USC 360i(g), list
FDA-assigned Recall Number or include a statement
97610227-FA
Patient Sequence Number1
Patient Age55 YR
Patient SexFemale
Patient Weight112 LB
-
-