It was reported that a transient ischemic attack occurred.A left atrial appendage (laa) closure procedure was performed, and a 31mm watchman flx pro closure device was implanted on (b)(6) 2026.The patient was discharged on plavix 75 mg and asa 81 mg.As a plavix non-responder, the patient was switched to brilinta 90 mg twice a day while inpatient.On (b)(6) 2026, the patient was admitted with cerebral vascular accident (cva) symptoms, the patient had left sided weakness, left facial droop, slurred speech and decreased sensation.On (b)(6) 2026, a head computed tomography (ct) was performed and imaging showed no acute findings.Carotid imaging demonstrated no flow-limiting stenosis.A magnetic resonance imaging (mri) could not be performed due to an incompatible pacemaker (pm).During the procedure a complete seal was noted and there were no changes to the seal of the closure device.The patient symptoms resolved within 24 hours, and the patient fully recovered.The patient was discharged home on brilinta 90mg twice a day.
|