• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: Dentsply Implants Manufacturing GmbH OsseoSpeed TX 3.5S - 11 mm; implant, endosseous, root-form

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

Dentsply Implants Manufacturing GmbH OsseoSpeed TX 3.5S - 11 mm; implant, endosseous, root-form Back to Search Results
Catalog Number 24932
Medical Device Problem Code Failure to Osseointegrate (1863)
Health Effect - Clinical Code Inadequate Osseointegration (2646)
Date of Event 11/25/2025
Type of Reportable Event Serious Injury
Event or Problem Description
It was reported that a patient experienced a dental implant loss.
 
Additional Manufacturer Narrative
Since this event resulted in a serious injury, it is reportable per 21 cfr part 803.The device was not evaluated because the issue is a known inherent risk of the device.We will continue to track and monitor the trend.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
OsseoSpeed TX 3.5S - 11 mm
Common Device Name
implant, endosseous, root-form
Manufacturer (Section D)
Dentsply Implants Manufacturing GmbH
rodenbacher chaussee 4
hanau hessen 63457
GM  63457
Manufacturer (Section G)
Dentsply Implants Manufacturing GmbH
rodenbacher chaussee 4
hanau hessen 63457
GM   63457
Manufacturer Contact
dan eager
221 w. philadelphia st.
suite 60w
york, PA 17401
+1(717)845-7511
MDR Report Key50697530
Report Number3013111692-2026-40415
Device Sequence Number13182954
Product Code DZE
UDI-Device Identifier07392532108372
UDI-Public07392532108372
Combination Product (Y/N)N
Initial Reporter CountryCH
PMA/510(K) Number
K053384
Number of Events Summarized1
Summary Report (Y/N)N
Device Implanted Year2025
Device Explanted Year2025
Serviced by Third Party (Y/N)N
Reporter Type Manufacturer
Report Source Foreign,Health Professional
Initial Reporter Occupation Dentist
Type of Report Initial
Report Date (Section B) 09/09/2026
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Operator of Device Health Professional
Device Catalogue Number24932
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 08/11/2026
Initial Report FDA Received Date09/09/2026
Was Device Evaluated by Manufacturer? (Y/N) No
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Outcome Attributed to Adverse Event Required Intervention;
Patient SexUnknown
-
-