BAXTER HEALTHCARE CORPORATION FlexiPort Disposable Blood Pressure Cuff; SOFT-11 Back to Search Results
Model Number SOFT-11
Medical Device Problem Codes Material Deformation (2976); Inaccurate Information (4051); Failure to Deflate (4060)
Health Effect - Clinical Code Cardiac Arrest (1762)
Date of Event 08/17/2026
Type of Reportable Event Serious Injury
Event or Problem Description
The customer reported concerns regarding the accuracy of non-invasive blood pressure (nibp) measurements obtained using disposable flexiport soft cuffs.Three days later, the customer provided the following additional information.Reportedly, a patient lost pulses at approximately 0930 and underwent resuscitation efforts.Following placement of an arterial line after the resuscitation, a discrepancy was observed between non-invasive blood pressure (nibp) cuff readings and arterial line pressure measurements.According to the report, the blood pressure cuff on the patient's arm consistently displayed measurements that were substantially lower than the arterial line readings.As an example, at approximately 1800, the blood pressure cuff reportedly displayed a reading of 64/41 mmhg while the arterial line reading was 105/53 mmhg.The customer further reported that at 1000, 1015, and 1100, the blood pressure cuff continued to display extremely low blood pressure readings when the cuff was not secured around the patient's arm and was reportedly positioned underneath the patient.The customer reported concern that the discrepancy between the nibp cuff readings and arterial line pressure measurements may have impacted the interpretation of the patient's blood pressure status.Furthermore, the customer reported that hospital staff had raised additional concerns regarding the disposable flexiport soft cuffs, including cuffs sliding down, retaining air, causing patient discomfort, and clips detaching during blood pressure measurements.The bp cuff involved in this case was returned for inspection.It is unclear which monitoring device was used with the reported bp cuff; however, it is noted that the facility predominantly employs non-baxter monitors.Additional information regarding the reported events were requested.Investigation is ongoing.
 
Additional Manufacturer Narrative
Flexiport pediatric through adult reusable blood pressure cuffs are noninvasive blood pressure cuffs intended for use in conjunction with non-automated and automated sphygmomanometers to determine blood pressure in pediatric through adult patients.An inspection of the device performed by a baxter technician was unable to verify the reported issues of inaccurate blood pressure readings or failure to deflate.The device passed functional testing and blood pressure accuracy testing.Visual inspection identified wear and tear of the cuff velcro.No further issues were identified.In this event, it was reported that the patient lost pulses and required resuscitation.This represents a life-threatening condition requiring immediate medical intervention and is therefore considered a serious injury.The customer subsequently identified a discrepancy between nibp cuff measurements and arterial line pressure readings, with the nibp readings reportedly being substantially lower than the arterial line readings.The exact cause of the reported discrepancy is undetermined at this time.An inspection of the returned device was unable to replicate the report of inaccurate readings, and the device passed all functional and accuracy testing.Additionally, it is unclear which monitoring device was used with the reported cuff during the event.Therefore, a potential contribution of the monitoring system to the reported discrepancy cannot be excluded.Based on the available information, a causal relationship between the reported device and the serious injury cannot be determined.Further investigation is on-going, if any additional and relevant information is received, it will be submitted in a supplemental report.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
FlexiPort Disposable Blood Pressure Cuff
Common Device Name
SOFT-11
Manufacturer (Section D)
BAXTER HEALTHCARE CORPORATION
deerfield IL
Manufacturer (Section G)
WELCH ALLYN PRODUCTS, MEXICO
emilio flores #2471-a2
caã¿â¿¿on del padre
tijuana, baja california NA 22203
MX   22203
Manufacturer Contact
25212 w. illinois route 120
round lake, IL 60073
+1(224)270-5355
MDR Report Key50753166
Report Number3006087789-2026-00023
Device Sequence Number9668013
Product Code DXQ
UDI-Device Identifier00732094188097
UDI-Public00732094188097
Combination Product (Y/N)N
Initial Reporter StateCO
Initial Reporter CountryUS
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source Health Professional,Company Representative
Type of Report Initial
Report Date (Section B) 09/14/2026
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Operator of Device Health Professional
Device Model NumberSOFT-11
Device Catalogue NumberSOFT-11
Was Device Available for Evaluation? Yes
Is the Reporter a Health Professional? No
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 08/17/2026
Initial Report FDA Received Date09/14/2026
Was Device Evaluated by Manufacturer? (Y/N) Yes
Is the Device Labeled for Single Use? (Y/N) No
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Reuse
Patient Sequence Number1
Concomitant Medical Products
and Therapy/Usage Dates
N/A.
Outcome Attributed to Adverse Event Life Threatening;
Patient SexUnknown
-
-