• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: Cordis US. Corp EXOSEAL; Device, Hemostasis, Vascular

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

Cordis US. Corp EXOSEAL; Device, Hemostasis, Vascular Back to Search Results
Catalog Number EX500
Medical Device Problem Code Mechanical Jam (2983)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 08/15/2026
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
Due to system limitations, section h6 required to input type of investigation, investigation findings, and investigation conclusions for an initial report.Pending additional information to complete investigation.This device is available for analysis, but the engineering report is not yet available.However, it will be submitted within 30 days upon receipt.Additional information is pending and will be submitted within 30 days upon receipt.
 
Event or Problem Description
As reported, the plug deployment button of a 5f exoseal vascular closure device (vcd) could not be pressed down after the indicator window changed to black-black.Hemostasis was achieved by manual compression.There was no reported patient injury.The operator was attempting to close the puncture site.There were no visible signs of device or package damage prior to use.The device was stored and prepared according to the instructions for use (ifu).The exoseal vcd and vascular sheath introducer were retracted together until pulsatile flow from the bleed-back indicator significantly slowed or stopped and until the indicator window changed to solid black.When depression of the button was attempted, the button would not depress at all.The indicator window did not show any red color during retraction.The device was not attempted to be deployed outside the patient¿s body.A non-cordis catheter sheath introducer was used.Femoral artery suitability was verified on angiography, including the vascular sheath introducer insertion angle of 30-45 degrees, and the vessel diameter was verified to be greater than or equal to 5 mm.There was no visible calcium or plaque at the puncture site, no access vessel tortuosity, no stent near the puncture site, and no stenosis greater than 50% at or near the puncture site.The target femoral site had not been closed with a closure device or manual compression less than 30 days before the procedure.There was no evidence of pre-existing hematoma, arteriovenous fistula, or pseudoaneurysm at the access site before exoseal vcd use.The exoseal vcd was used in a diagnostic procedure with a retrograde approach.The patient¿s body mass index (bmi) was not greater than 40.The physician had achieved certification on the use of the exoseal vcd.The device will be returned for evaluation.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
EXOSEAL
Common Device Name
Device, Hemostasis, Vascular
Manufacturer (Section D)
Cordis US. Corp
14201 nw 60 avenue
miami lakes FL 33014
Manufacturer (Section G)
Cordis US Corp.
14201 nw 60 avenue
miami lakes FL 33014
Manufacturer Contact
karla castro
santiago troncoso 808
juarez, chihuahua 32574
MX   32574
+011(786)3138372
MDR Report Key50766815
Report Number9616099-2026-01272
Device Sequence Number9195632
Product Code MGB
UDI-Device Identifier10705032058872
Combination Product (Y/N)N
Initial Reporter CountryCH
PMA/510(K) Number
P100013
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)N
Reporter Type Manufacturer
Report Source Foreign,Health Professional,Company Representative
Initial Reporter Occupation Other Health Care Professional
Type of Report Initial
Report Date (Section B) 09/14/2026
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Catalogue NumberEX500
Device Lot Number18518875
Was Device Available for Evaluation? Yes
Date Returned to Manufacturer08/28/2026
Is the Reporter a Health Professional? Yes
Was the Report Sent to FDA? No
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 08/18/2026
Initial Report FDA Received Date09/15/2026
Was Device Evaluated by Manufacturer? (Y/N) No
Date Device Manufactured10/21/2025
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Concomitant Medical Products
and Therapy/Usage Dates
Terumo catheter sheath introducer.
Patient Age48 YR
Patient SexMale
Patient Weight132 LB
-
-