MAUDE Adverse Event Report: INTUITIVE SURGICAL, INC None; ENDOSCOPE

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

INTUITIVE SURGICAL, INC None; ENDOSCOPE Back to Search Results
Model Number 470056-11
Medical Device Problem Code Output Problem (3005)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 07/28/2026
Type of Reportable Event Malfunction
Event or Problem Description
It was reported that prior to the start of a da vinci-assisted surgical procedure, the zero degree endoscope plus was observed as needing repair the procedure was completed as planned with no reported injury.
 
Additional Manufacturer Narrative
Intuitive surgical, inc.(isi) received the da vinci product to perform failure analysis.The zero (0) degree endoscope plus was analyzed and found with damage to the distal end, including a cracked distal window at the distal tip and a broken or detached piece that could fall into the patient.Mechanical damage to the distal tip was also observed.The endoscope cable connector exhibited customer-added labels or markings.The endoscope underwent friction testing using a screening aid to manually rotate the adapter and detect friction; the camera instrument adapter did not rotate properly, noises were heard during testing, and binding was confirmed.The endoscope cable was visually inspected and found with a defect at zone c near the endoscope housing.Visual inspection confirmed visible light shining through the cable insulation jacket when the cable was connected to the internal system (or equivalent) and illumination was powered on.The complaint regarding the instrument needed repair was confirmed by failure analysis.The probable root cause can be attribute to conditions during user, such as inadvertent collisions with hard surfaces or falling endoscope or caused by improper cleaning during reprocessing.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
None
Common Device Name
ENDOSCOPE
Manufacturer (Section D)
INTUITIVE SURGICAL, INC
3410 central expressway
santa clara CA 95051
Manufacturer (Section G)
INTUITIVE SURGICAL, INC
3410 central expressway
santa clara CA 95051
Manufacturer Contact
izabel nielson
3410 central expressway
santa clara, CA 95051
+1(408)523-2100
MDR Report Key50767493
Report Number2955842-2026-38943
Device Sequence Number15806312
Product Code GCJ
UDI-Device Identifier00886874116562
Combination Product (Y/N)N
Initial Reporter StateMN
Initial Reporter CountryUS
PMA/510(K) Number
K191736
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source Other
Initial Reporter Occupation Biomedical Engineer
Remedial Action Other
Type of Report Initial
Report Date (Section B) 09/15/2026
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Model Number470056-11
Device Catalogue Number470056
Device Lot NumberN/A
Was Device Available for Evaluation? Yes
Date Returned to Manufacturer08/05/2026
Is the Reporter a Health Professional? No
Initial Date Received by Manufacturer 08/20/2026
Initial Report FDA Received Date09/15/2026
Was Device Evaluated by Manufacturer? (Y/N) Yes
Date Device Manufactured09/15/2023
Is the Device Labeled for Single Use? (Y/N) No
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
If action reported to FDA under 21 USC 360i(g), list
FDA-assigned Recall Number or include a statement
N/A
Patient Sequence Number1
Concomitant Medical Products
and Therapy/Usage Dates
da Vinci Instruments and Accessories
Patient SexUnknown
-
-