MIS Implants Technologies Ltd. SEVEN internal hex. implant dia. 3.30 L 11.50mm NP; implant, endosseous, root-form Back to Search Results
Catalog Number MF7-11330
Medical Device Problem Code Loss of Osseointegration (2408)
Health Effect - Clinical Code Inadequate Osseointegration (2646)
Date of Event 08/07/2026
Type of Reportable Event Serious Injury
Event or Problem Description
It was reported that a patient experienced a dental implant loss.
 
Additional Manufacturer Narrative
Since this event resulted in a serious injury, it is reportable per 21 cfr part 803.The device was not evaluated because the issue is a known inherent risk of the device.We will continue to track and monitor the trend.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
SEVEN internal hex. implant dia. 3.30 L 11.50mm NP
Common Device Name
implant, endosseous, root-form
Manufacturer (Section D)
MIS Implants Technologies Ltd.
p.o. box 7
bar lev industrial park 20156 00
IS  2015600
Manufacturer (Section G)
MIS Implants Technologies Ltd.
p.o. box 7
bar lev industrial park 20156 00
IS   2015600
Manufacturer Contact
dan eagar
221 w. philadelphia st.
suite 60w
york, PA 17401
+1(717)845-7511
MDR Report Key50778362
Report Number3004203816-2026-25921
Device Sequence Number18626782
Product Code DZE
UDI-Device Identifier07290108999570
UDI-Public07290108999570
Combination Product (Y/N)N
Initial Reporter CountryFR
PMA/510(K) Number
K180282
Number of Events Summarized1
Summary Report (Y/N)N
Device Implanted Year2026
Device Explanted Year2026
Serviced by Third Party (Y/N)N
Reporter Type Manufacturer
Report Source Foreign,Health Professional
Initial Reporter Occupation Dentist
Type of Report Initial
Report Date (Section B) 09/15/2026
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Operator of Device Health Professional
Device Catalogue NumberMF7-11330
Device Lot NumberW25007071
Was Device Available for Evaluation? Yes
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 08/19/2026
Initial Report FDA Received Date09/15/2026
Was Device Evaluated by Manufacturer? (Y/N) No
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Outcome Attributed to Adverse Event Required Intervention;
Patient SexUnknown
-
-