Biosense Webster Inc QDOT MICRO; Catheter, percutaneous, cardiac ablation, for treatment of atrial fibrillation
|
Back to Search Results |
|
| Catalog Number |
D139504 |
| Medical Device Problem Code |
Adverse Event Without Identified Device or Use Problem (2993)
|
| Health Effect - Clinical Codes |
Cardiac Arrest (1762); Hemorrhage/Blood Loss/Bleeding (1888); Ventricular Fibrillation (2130)
|
|
Type of Reportable Event
|
Death
|
|
Event or Problem Description
|
|
It was reported that a patient underwent an atrial fibrillation ablation procedure with a qdot micro catheter and a watchman appendage closure wherein the patient experienced cardiac arrest that required cardiopulmonary resuscitation (cpr), pacing and ecmo, ventricular fibrillation that required cardioversion, and hemorrhage.The patient expired.At the conclusion of atrial fibrillation ablation, during the process of extubating, patient developed bradycardia followed by hypotension.Soon after, loss of pulse was noted by anesthesiologist and cpr was started.X-ray showed that the right ventricle was not moving.No effusion was noted via trans-esophageal echocardiogram (tee).Pulse was noted after initial cpr for a short period.Transvenous pacemaker catheter was inserted.Patient developed ventricular fibrillation soon after and shocked to restore sinus rhythm was performed.Extracorporeal membrane oxygenation was inserted with normalization of blood pressure.However, abdominal distention was noted by echocardiogram that there was blood around the patient¿s liver.Decision was made to have a ct, results are unknown.Patient was placed in the intensive care unit where he passed away during early hours of the next morning (b)(6) 2026.The physician¿s opinion on the cause of this adverse event is that protamine was given too fast or in a large dose can cause severe anaphylactoid reactions, profound hypotension, pulmonary vasoconstriction, and cardiovascular collapse.
|
| |
|
Additional Manufacturer Narrative
|
|
Device investigation details:
an analysis of the product could not be performed since a physical sample was not received for evaluation.However, if the product is received at a later date, the investigation will be updated as applicable.A manufacturing record evaluation was performed for the finished device number lot 31875249l and no internal actions related to the complaint were found during the review.As part of our company quality system process, all devices are manufactured, inspected, and distributed to approved specifications.This report is being submitted pursuant to the provisions of 21 cfr, part 803.This report may be based on information which has not been investigated or verified prior to the required reporting date.This report does not reflect a conclusion by biosense webster inc., or its employees that the report constitutes an admission that the product, biosense webster inc., or its employees caused or contributed to the potential event described in this report.If information is obtained that was not available for the initial report, a follow-up report will be filed as appropriate.Manufacturer's ref.# (b)(4).
|
| |
|
Search Alerts/Recalls
|
|
|