| Catalog Number |
NOD10LPT |
| Medical Device Problem Codes |
Break (1069); Material Separation (1562)
|
| Health Effect - Clinical Code |
No Clinical Signs, Symptoms or Conditions (4582)
|
| Date of Event |
08/27/2026
|
|
Type of Reportable Event
|
Malfunction
|
|
Event or Problem Description
|
|
On (b)(6)2026, a patient underwent a ultrasound guided percutaneous percutaneous drainage catheter placement procedure using navarre opti drain drainage catheter.During the procedure, the sure loktm thread was allegedly broken.The affected drainage catheter was replaced with a new drainage catheter, and the procedure was completed successfully.There was no reported patient injury.
|
| |
|
Event or Problem Description
|
|
On (b)(6)2026, a patient underwent a ultrasound guided percutaneous percutaneous drainage catheter placement procedure using navarre opti drain drainage catheter.During the procedure, the sure loktm thread was allegedly broken.The affected drainage catheter was replaced with a new drainage catheter, and the procedure was completed successfully.There was no reported patient injury.
|
| |
|
Additional Manufacturer Narrative
|
|
H11: as the lot number for the device was provided, a review of the device history records will be performed.The device has not been returned to the manufacturer for evaluation.However, photos were provided for review.The investigation of the reported event is currently underway.Section a through f: the information provided by bd represents all of the known information at this time.Despite good faith efforts to obtain additional information, the complainant / reporter was unable or unwilling to provide any further patient, product, or procedural details to bd.
|
| |
|
Additional Manufacturer Narrative
|
|
H11: manufacturing review: a manufacturing review was not required as this is the only complaint reported to date for this lot.Investigation summary: the physical device was not returned for evaluation, two photos were provided for review.The first photo shows the partial view of a clinician holding the drainage catheter and thread.The thread noted to be completely detached from the proximal hub thread hole.The second photo shows the complete view of a fully detached thread, and the drainage catheter is not visible in the provided photo.Therefore, the investigation is confirmed for the reported thread break and material separation issues for both the devices.The definitive root cause could not be determined based upon available information.Labeling review: as the reported event did not allege a labeling or use related issue, a labeling review is not required.G3, h6 (method, result, conclusion).Section a through f : the information provide by bd represents all the known information at this time.Despite good faith efforts to obtain additional information, the complainant/reporter was unable or unwilling to provide any further patient, product, or procedural details to bd.
|
| |
|